• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

2 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x RDS 4 Helios Transformer Controller With Motor Protection2 x Round ceiling diffuser 200mm1 x Elta Variable Speed Drive IP66 - 2.2KW1 x FU 075 52 Frequency Inverter (IP20)1 x FRQ5-4A V2 Inverter Speed Controller1 x FRQ-10A V2 Inverter Speed controller1 x Helios TSD 3.0 Transformer Speed Control (400v)1 x FU 15 40 Frequency Inverter1 x Elta Variable Speed Drive IP66 - 7.5KW1 x ATEX rated 3-phase Speed Control - R-DK4 KT (EX)1 x Elta Variable Speed Drive IP66 - 2.2KW (1ph to 3ph)1 x FRQ5-10A Inverter Speed controller1 x FU 15 16 Frequency Inverter1 x Elta Variable Speed Drive IP66 - 5.5KW1 x Elta Variable Speed Drive IP66 - 1.5KW1 x Frequency converter RUCK - FU 075 201 x Elta Variable Speed Drive IP66 - 4.0KW1 x Frequency converter FU 075 14 - IP661 x FU 22 25 Frequency Inverter1 x FU 075 04 Frequency Inverter (IP20)1 x Frequency converter RUCK - FU 075 211 x FU 22 04 Frequency Inverter1 x Elta 10 Amp Electronic single phase speed controller.1 x ELTA - Three Phase Transformer 10amps1 x ELTA - Three Phase Transformer 3amps1 x Circular Ceiling Diffuser - TST 1251 x ELTA - Single Phase Transformer 2amps1 x NKS-D swirl diffuser v-300 x 300mm1 x Electronic extractor fan speed controller - FSC 1.51 x Circular Ceiling Diffuser - TST 1001 x PCA Diffuser - PCA-3151 x JSR 200 Painted RAL50181 x Round ceiling diffuser 400mm1 x Curved Blade Grille 600x600 (2way blow)1 x EC6H - Reversible Group Fan Electronic Controller1 x Circular Ceiling Diffuser - TST 2001 x Airvent ceiling fan controller1 x ELTA - Single Phase Transformer 16amps1 x Elta 3 Amp Electronic single phase speed controller with TK1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x Circular Ceiling Diffuser - TST 1601 x Elta 2 Amp Electronic single phase speed controller.1 x ELTA - Single Phase Transformer 12amps1 x Balance S Diffuser - NO RING - 100mm1 x Elta 3 Amp Electronic single phase speed controller.1 x Elta 6 Amp Electronic single phase speed controller with TK1 x EFSC-3N- Single Phase Speed Control1 x ELTA - Single Phase Transformer 8amps1 x Round ceiling diffuser 250mm1 x ELTA - Single Phase Transformer 4amps1 x COM-31 x Round ceiling diffuser 300mm1 x AIRVENT speed control - AIR4019611 x Round ceiling diffuser 350mm1 x Elta 6 Amp Electronic single phase speed controller.1 x PCA Diffuser - PCA-2501 x EFSC-6N- Single Phase Speed Control1 x ELTA - Single Phase Transformer 10amps1 x Run On Timer - 5s - 4hrs - RT5A1 x Remote Timer Control - 13511 x Push Timer Switch - ZA41 x Helios ZNE Electronic Fan Overrun Timer1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Time Delay Unit - DT20B1 x 7 Day Programmable TIMECLOCK1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x ACO8AC/EC AutoChangeover panel1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x EM30-24 Electro-Mechanical Control Panel1 x ACO 149-ACO1/EDV2 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Elta ACO Panel 149-ACO18B1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x Easy-fix termination kit - High Rise Ventilator - EFT1 x EC-Vent Room Unit1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x Elta Wall Cowl SWC56/631 x Elta Louvre Shutter - 400mm1 x Elta Wall Cowl SWC25/311 x Elta Wall Cowl SWC35/401 x Elta Wall Cowl SWC45/501 x Jet Cowl - 315mm1 x Egg Crate Grille with G2 Dust panel filter 1 inch- 300x3001 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 7101 x Egg Crate Grille with Dust panel filter 1 inch- 595x5951 x Single Deflection Grille 400mm with OBD damper1 x Transformer speed controller - ATC1 - 1.5 Amps
Reviews
Duct Mounted Inline Filter - EU4
Duct Mounted Inline Filter - EU4
£ 44.99

Well made and robust, but it was not use for my application ...