• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x MV-Silent 350 Bathroom Extractor Fan Kit - Timer1 x Speed Controller - REB11 x Speed Controller - REB1-N1 x Spiral Ducting 3 Meters - 100mm1 x Duct Termination with Mesh - 200mm3 x Remote Timer Control - 13511 x Time Delay Unit - DT20B1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Transformer 5 Speed Controller - ATC1-4TK1 x Helios TSW 1.5 Amp Transformer speed controller1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans2 x Helios TSW 3 Amp Transformer speed controller2 x Remote controller FLEX - for VEKO INT2 x Helios TSW 7.5 Amp Transformer speed controller1 x Helios TSW 0.3Amp Compact Transformer speed controller2 x RDS 11 Helios Transformer Controller With Motor Protection1 x Helios TSW MCB Amp Transformer speed controller1 x Systemair Save Connect 2.0 Internet Module1 x RDS 7 Helios Transformer Controller With Motor Protection1 x Helios TSW 10 Amp Transformer speed controller1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Vent Axia ACM 125 inline mixed flow duct fan1 x Transformer 5 Speed Controller - ATC1-2TK1 x DEF-140T Inlet Guard for the CBT-100N1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Vent Axia ACM 150 inline mixed flow duct fan1 x Push Timer Switch - ZA41 x Isolator Switch - ISOSW1 x MWS 3 – Transformer Controller With Motor Protection1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x CS2 Current Switch1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Elta 3 Amp Electronic single phase speed controller with TK1 x Transformer 5 Speed Controller - ATC1-10TK1 x Helios HQW-200/2 - IP551 x MWS 1.5 – Transformer Controller With Motor Protection1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x WS - Reversing Switch from Helios Fans1 x Two Speed Switch - REGUL-21 x MV-B Dual Switch for use with Helios HQW plate fans,1 x Helios HQW-630/4 - IP551 x Transformer (silent) speed controller - RE 3.0 Amp1 x CBS-60 Outlet Flange for CSB/CBT-601 x Electronic extractor fan speed controller - FSC 1.51 x Helios HQW-200/4 - IP551 x Airvent ceiling fan controller1 x Transformer (silent) speed controller - RE 1.5 Amp2 x FAST-TRACK RANGE 75mm - Click Ring (1 bag of 10)1 x Skyflow SSR Horizontal Roof Cowl SSR31/35B1 x Speed Controller - REB51 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Vent Axia ACM 200 inline mixed flow duct fan1 x Transformer Speed Control - RTRE- 7.0Amp1 x Speed Controller - REB61 x Multiflow SMB550/4-1AC