• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x KVK SLIM 250 EC - Centrifugal Circular Duct Fan1 x CBT-130N Centrifugal ATEX II 2G Exd IIB T41 x KVK Slim 100 - Low profile Semi Acoustic Box Fan1 x Soler & Palau TCBT/2-315/H-B E70 - IP551 x Axial Roof mounted Extract/Supply Fan- -HCTT/4-1000-A 5.5kw1 x GXC9 - High Performance Extract Fan1 x 204 x 60mm Duct to Duct Connector for use with Insulated Thermal Ducting1 x Helios GigaBox 400mm GBW 400/4 centrifugal1 x Spiral Duct Grille Termination - 250mm1 x CVAT/4-4000/400 ND 0.37Kw (230/400V50HZ) EXDIIBHT4 - ATEX RATED CABINET FAN1 x Singleflow SSDL250-1EC1 x Raptor SDA315/4-1AC1 x 100mm - 125mm Round Reducer1 x Anti Vibration Mounts - Small - Pack of 4 - AVM21 x CBT-100 N (230/400V50HZ) LG270-EXDIIBT41 x Classic SAX30/12ARB Wall Mounted1 x CC-314 M Cased Axial Fan (Single Phase)1 x Classic SAX23/9AR Window/Wall Mounted1 x KVK SLIM 100 EC - Centrifugal Circular Duct Fan1 x Acoustic MiniBox Fan - MINI-BOX 2501 x Acoustic Commercial Kitchen Inline Exhaust Fan - MPS (Three Phase) - 250mm1 x Axial Roof mounted Extract/Supply Fan- -HCTT/4-1000-B 5.5kw1 x PRIO 400 EC, Axial circular duct fan - EC motor1 x Elta SPA500/4-1EC - IP541 x 150mm Round Connector1 x Soler & Palau VFD-T inverter 5 amp IP541 x AL 315 EC 01 AXIALINE - High Performance Long Cased Axial Fan1 x Acoustic Box Fans (Inline) - CAB-250N1 x Sentinel D-BOX 100S1 x 125mm Round Connector1 x HRB/4-500-35-BPNC1 x Ancillary Sealing Band - 250mm1 x WOODS 31JM/16/4/5/34-DEG 4POLE 1PH LONG CASED AXIAL FAN1 x Metal Inline Fan - VENT-400K - T (3 Phase)1 x Etaline 400mm
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 50.56

I have a loft mount extractor fan which was very noisy. I ...