• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x MTS10- extractor fan 3 step switch1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x Easy-fix termination kit - High Rise Ventilator - EFT1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Elta Wall Cowl SWC56/631 x Elta Wall Cowl SWC35/401 x Elta Wall Cowl SWC45/501 x GRA-100 External Grill by S&P1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 7101 x Elta Wall Cowl SWC25/311 x Silentub - STUB 2002 x Run On Timer - 5s - 4hrs - RT5A1 x Economy Airvent 150mm Fan With Pullcord & Shutters1 x Economy Airvent 100mm Fan with Timer1 x DV-ROF-V-225 Roof mounted unit1 x DV-ROF-V-315 Roof mounted unit1 x Manrose 150mm - XF150BP1 x 18M - 80mm PVC flexible ducting1 x Manrose 150mm - XF150BHP1 x Manrose T12 STANDARD Transformer- T12S1 x Economy Airvent 150mm Fan1 x Control board kit Smarty 4X P 1.1 F2 Fan 230V1 x Economy Airvent 100mm Fan with Timer/Humidistat/Pullcord1 x Elta - SMT 125 Mixvent Inline Fan - Clearance Stock Line1 x D2E-146-AP47-751 x Economy Airvent 100mm Fan with Timer & Shutter1 x HQS Bathroom Axial Flow Fan - 125mm1 x CTVT/4-400 High Temp Roof Fan - 51369260001 x Fresh Air control carbon filter - 125mm1 x HIMF - Mixed Flow Fan 100mm Inline Fan1 x LF-ME04F071LC3AC1 x Manrose Auto Shutter - XF150AP1 x Maico EN31- Wall Mounted Fan1 x Small Centrifugal Fans CBM/2-133/190 185w1 x Manrose 150mm - XF150BTP1 x G2E160−AL19−56 FLUE FAN1 x D2E146-AP47-C11 x D2E146-AP47-331 x EBM-Papst D3G133-BF05-14 Double inlet1 x Small Centrifugal Fan - CBM/4-180/184-150 W1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x Elta 10 Amp Electronic single phase speed controller.1 x TDP-D Pressure Sensor with Display1 x Helios TSW 1.5 Amp Transformer speed controller1 x ELTA - Single Phase Transformer 2amps1 x EC6H - Reversible Group Fan Electronic Controller2 x Electronic extractor fan speed controller - FSC 1.51 x Elta 3 Amp Electronic single phase speed controller.1 x Elta 3 Amp Electronic single phase speed controller with TK1 x Elta 2 Amp Electronic single phase speed controller.1 x EFSC-3N- Single Phase Speed Control1 x DEF-140T Inlet Guard for the CBT-100N1 x Airvent ceiling fan controller1 x ELTA - Single Phase Transformer 4amps1 x AIRVENT speed control - AIR4019612 x Remote Timer Control - 13511 x ELTA - Single Phase Transformer 8amps1 x EFSC-6N- Single Phase Speed Control1 x COM-31 x Elta 6 Amp Electronic single phase speed controller.1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Isolator Switch - ISOSW1 x ELTA - Single Phase Transformer 12amps1 x Systemair Save Connect 2.0 Internet Module1 x ELTA - Single Phase Transformer 10amps1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Time Delay Unit - DT20B1 x Push Timer Switch - ZA41 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Two Speed Switch - REGUL-21 x Transformer (silent) speed controller - RE 3.0 Amp1 x CBS-60 Outlet Flange for CSB/CBT-601 x Speed Controller - REB51 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x ACO8AC/EC AutoChangeover panel1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Transformer Speed Control - RTRE- 1.5Amp1 x EC-Vent control board1 x Elta ACO Panel 149-ACO14E1 x CONTROL ECOWATT - Basic1 x ACO 149-ACO1/EDV1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection
Reviews
Transformer (silent) speed controller - RE 1.5 Amp
Transformer (silent) speed controller - RE 1.5 Amp
£ 132.29

Unbelievable! With TDmixvent500: noise reduction minimum 50%...