400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x RUCK MTP 20, 10K, Speed control1 x HRB/6-710-30-BQC1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Elta ACO Panel 149-ACO14E1 x CONTROL ECOWATT - Basic1 x EC-Vent control board1 x ACO 149-ACO1/EDV1 x MWS 1.5 – Transformer Controller With Motor Protection1 x EM30-24 Electro-Mechanical Control Panel1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x EC-Vent Room Unit3 x Systemair Save Connect 2.0 Internet Module1 x Elta ACO Panel 149-ACO18B1 x EM30-24 Control Panel Commissioning Service1 x Biflow SB400-CON2-3 - High Temperature Bifurcated Fan1 x Egg Crate Grille with G2 Dust panel filter 1 inch- 300x3001 x Egg Crate Grille with Dust panel filter 1 inch- 595x5951 x Single Deflection Grille 400mm with OBD damper1 x Non Vision 150mm x 150mm (Air Transfer) Grille - With Flange - MILL FINISH1 x Mini Diffuser - 100mm1 x Egg Crate Grille with Dust panel filter 1 inch- 300x3001 x MTS10- extractor fan 3 step switch1 x Vent Axia ACM 150 inline mixed flow duct fan1 x Vent Axia ACM 200 inline mixed flow duct fan3 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost2 x Helios TSW MCB Amp Transformer speed controller2 x Helios TSW 10 Amp Transformer speed controller2 x DEF-140T Inlet Guard for the CBT-100N2 x Vent Axia ACM 125 inline mixed flow duct fan2 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x REU 3amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Transformer 5 Speed Controller - ATC1-4TK1 x Helios TSW 1.5 Amp Transformer speed controller1 x Transformer speed controller - ATC1 - 1.5 Amps1 x Remote controller FLEX - for VEKO INT1 x Helios TSW 7.5 Amp Transformer speed controller1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Vent Axia ACM 100 inline mixed flow duct fan2 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Transformer 5 Speed Controller - ATC1-10TK1 x Helios TSW 3 Amp Transformer speed controller2 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x CS2 Current Switch1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp2 x Isolator Switch - ISOSW1 x TD EVO-100 PF ECOWATT - Environmentally Friendly Energy Efficient Inline Fan1 x MWS 3 – Transformer Controller With Motor Protection1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x Elta 6 Amp Electronic single phase speed controller with TK1 x ERR 20/1 Centrifugal inline fan1 x Transformer 5 Speed Controller - ATC1-8TK1 x MV-B Dual Switch for use with Helios HQW plate fans,2 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT1 x WS - Reversing Switch from Helios Fans1 x Elta 3 Amp Electronic single phase speed controller with TK1 x ERR 31/1 Centrifugal inline fan1 x Electronic extractor fan speed controller - FSC 1.52 x TG-K Duct temperature sensor1 x 7 Day Programmable TIMECLOCK1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Elta 10 Amp Electronic single phase speed controller.3 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT2 x Transformer (silent) speed controller - RE 3.0 Amp2 x Helios HQW-630/4 - IP551 x Transformer 5 Speed Controller - ATC1-2TK3 x KMBI 315 Connector rectangular/circular to install on the discharge of CMT1 x CBS-60 Outlet Flange for CSB/CBT-601 x Skyflow SSR Horizontal Roof Cowl SSR31/35B2 x TG-K3/NTC10-01 - Duct temperature sensor1 x Helios HQW-200/4 - IP552 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x Transformer (silent) speed controller - RE 1.5 Amp1 x Speed Controller - REB31 x Skyflow SSR Horizontal Roof Cowl SSR80B1 x Airvent ceiling fan controller1 x Transformer Speed Control - RTRE- 7.0Amp1 x CBA-60 Inlet Flange for CBT-602 x Remote Timer Control - 13511 x Transformer (silent) speed controller - RE 5.0 Amp1 x Push Timer Switch - ZA41 x Helios HQW-315/4 - IP551 x CBM 9-9 550w 4P VR (Open Motor)1 x Transformer Speed Control - RTRE- 1.5Amp2 x KMBI 250 Connector rectangular/circular to install on the discharge of CMT1 x Multi Input Run On Timer - 0 - 20min - CFCU
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 58.40

I have a loft mount extractor fan which was very noisy. I ...