• Model:DKHM355-4SW

Rosenberg ATEX DKHM 355-4SW.110.5DF-E75

£ 1,494.95 (excl. VAT)

£ 1,793.94 (inc. VAT)


ATEX DKHM 355-4SW.110.5DF-E75

400VD, 50Hz, Zone1
IP44, Mot. 106-35, KS 3,0m
Atex II 2G Ex h IIB+H2 T3GbX

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Those fans are designed and manufactured to be operated in vaporous explosive atmosphere. They are marked in accordance with the Atex directive 2014/34/EU: II 2G Ex h IIB+H2 T3 Gb X

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


DKHM 355-4_W.110.5DF II 2G Ex h IIB+H2 T3 Gb X - Specification Sheets

1 x CK-60F Kit1 x Soler & Palau - HCBT/4-710/H - IP651 x 220x90mm Insulated Rectangular Horizontal 90° Bend1 x 220x90mm x 1m Insulated Rectangular Duct1 x Soler & Palau TCBT/2-315/H-B E70 - IP551 x Elta SLC450-1EC -IE5 Motor- IP551 x Soler & Palau - Contra Rotating TCBTx2-450 - IP651 x Ducting Y Piece - 250mm1 x Duct Termination with Mesh - 250mm1 x Inline Axial Fan - VOK-C 3151 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 400mm1 x 1mtr Round Ducting - 150mm1 x *VORT HRW 30 MONO Evo HCS WIFI - Single Room Heat Recovery Unit,1 x *VORT HRW 30 MONO Evo HCS - Single Room Heat Recovery Unit,1 x Revolution SLCX ATEX Long Cased Axial Flow Fan SLCX400/2-3 Three Phase1 x Three Phase ATEX Compact axial fan - 400mm - compactATEX71 x GENIOX 11 Internal Mounted Unit1 x Spiral Ducting 3 Meters - 315mm1 x 150mm Wall Duct - 350mm1 x FlameProof Plate Axial Fan - Three Phase - 10.5 inches - Eexd IIC T4 -2pole1 x TD2000 Mixvent - 315mm1 x Raptor SDA500/6-1AC1 x HRT/6-710/30-BQ E21 x Elta SLC450/2-1AC - IP551 x KTEX 50-30-4 Fan (ATEX)1 x Elta Turboflow-TF - 450mm - Single phase1 x Helios GigaBox 315mm GBW 315/4 centrifugal1 x WOODS 31JM/16/4/5/34-DEG 4POLE 1PH LONG CASED AXIAL FAN1 x Raptor SDA450/4-1EC1 x Belt Drive Cased Axial Fan - 710mm - H version1 x Etaline 315mm - D2 01 3 Phase1 x Belt Drive Cased Axial Fan - 800mm - G version1 x Elta SLC500/4B-3AC - IP551 x AXC 315-6/11-2(B)-PV 300*C - Smoke Extract Fan1 x Raptor SDA500/4-3EC1 x filter pack (set of 2) pt no. 4438891 x CADB/T-HE PRO-REG Series1 x Revolution SLCX ATEX Long Cased Axial Flow Fan SLCX500/4-3 Three Phase1 x Soler & Palau TCBB/4-315/H - IP441 x Elta Turboflow-TF - 500mm(A) - Three phase1 x 204 x 60mm Duct to Duct Connector for use with Insulated Thermal Ducting1 x Commercial Activated Carbon Filters - Panel Type - 24" x 24" x 2" - ACP1 x Jetflow-HIT Metal inline - 315mm1 x Elta SLC315/4-3AC - IP551 x HCFB/4-315mm plastic impeller plate fan1 x DV-ROF-V-315 Roof mounted unit1 x Elta SCP500-1EC - IP551 x DKEX 315-4 Centrifugal High Performance ATEX Fan1 x Elta SLC500/4A-3AC - IP551 x *VORT HRW 30 MONO Evo - Single Room Heat Recovery Unit,1 x Euro Series - Case Axial - ESC500141 x GENIOX 11 Roof Mounted External Unit1 x Activated Carbon Discarb Cell - Grade 50 - EXTRA DUTY - 445H x 445W x 595Dmm ACTUAL1 x Revolution SLCX ATEX Long Cased Axial Flow Fan SLCX710/4-3 Three Phase1 x Helios VARW 450/4 - TK1 x AL 315 D2 01 - High Performance Long Cased Axial Fan (3 phase)1 x Elta SCP710/6/8-3AC - IP551 x Economy Airvent 100mm Fan with Timer1 x FlameProof Plate Axial Fan - Single Phase - 10.5 inches - Eexd IIC T4 -4pole
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 10.53

Look good, works well, except the shaft of the lanellae cuts...