• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x Economy Airvent 150mm Fan With Pullcord & Shutters1 x Economy Airvent 100mm Fan with Timer1 x Same Day Shipping Surcharge - City Sprint1 x DV-ROF-V-225 Roof mounted unit2 x DPD 12PM Delivery Surcharge1 x Small Centrifugal Fan - CBM/4-160/150-125 W1 x G2E160−AL19−56 FLUE FAN1 x EBM-Papst D3G133-BF05-14 Double inlet1 x D2E146-AP47-331 x Manrose Window Extractor - WF150AP1 x Small Centrifugal Fan - CBM/4-180/184-150 W1 x Speed Controller - REB1-N1 x Transformer Speed Control - RTRE- 1.5Amp1 x CBT-100N Centrifugal1 x CBT-80N Centrifugal1 x CBB-60N Centrifugal1 x Dektite Combo Pipe Flashing - DC210REC1 x CBM 7/9 4p 300W RE-VR1 x Electronic extractor fan speed controller - FSC 1.51 x REE-1 Electronic Speed Controller1 x Speed Controller - REB2.5-N1 x ADH E0-250 Flange - 0250 ADHE/RDHE1 x EBM-Papst D2E097-BK76-98 Double inlet1 x Speed Controller - REB51 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Small Centrifugal Fans CBM/2-133/190 185w1 x Transformer 5 Speed Controller - ATC1-4TK1 x ERR 20/1 Centrifugal inline fan1 x 204x60mm Insulated Rectangular Horizontal 90° Bend1 x CBA-100 Inlet Flange for CBT-1001 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost2 x Vent Axia ACM 150 inline mixed flow duct fan1 x RTRD - Three Phase Speed Controller - 2 Amp1 x RTRD - Three Phase Speed Controller - 4 Amp1 x RR EC 160 Centrifugal inline fan - Energy Efficient Motor1 x Helios TSW 1.5 Amp Transformer speed controller1 x TEM 035 - 5 Speed Transformer Speed Control1 x Helios HQW-200/2 - IP551 x Transformer (silent) speed controller - RE 3.0 Amp1 x Helios TSW 0.3Amp Compact Transformer speed controller1 x Transformer 5 Speed Controller - ATC1-8TK1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT1 x Transformer 5 Speed Controller - ATC1-10TK1 x MV-B Dual Switch for use with Helios HQW plate fans,1 x CBS-60 Outlet Flange for CSB/CBT-602 x Vent Axia ACM 200 inline mixed flow duct fan2 x Vent Axia ACM 100 inline mixed flow duct fan1 x Helios HQW-200/4 - IP551 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)2 x Vent Axia T-Series Controller1 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x KMBI 250 Connector rectangular/circular to install on the discharge of CMT1 x Transformer (silent) speed controller - RE 5.0 Amp1 x Envirovent 4 Way Remote Control Switch - SWHBKRF-41 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Envirovent G4 Filter - SL-G4/F71 x Transformer Speed Control - RTRE- 7.0Amp1 x CBA-60 Inlet Flange for CBT-601 x MTV-1/010 Controller 0 to 10V+
Reviews
Soler & Palau TCBB/4-450/H - IP65
Soler & Palau TCBB/4-450/H - IP65
£ 505.88

Delivered super promptly yesterday, next day. Only just fitt...