Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

3 x Envirovent 4 Way Remote Control Switch - SWHBKRF-41 x TTC-2000 Three phase electric heater controller2 x Vent Axia ACM 100 inline mixed flow duct fan1 x ACO8AC/EC AutoChangeover panel1 x CONTROL ECOWATT - Basic1 x EM30-24 Electro-Mechanical Control Panel1 x Elta ACO Panel 149-ACO18B1 x EC-Vent Room Unit2 x Systemair Save Connect 2.0 Internet Module1 x EM30-24 Control Panel Commissioning Service2 x Vent Axia ACM 125 inline mixed flow duct fan2 x TG-K Duct temperature sensor2 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)2 x Envirovent G4 Filter - SL-G4/F72 x Transformer (silent) speed controller - RE 3.0 Amp1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x REB-CVF 0-10v Controller1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Easy-fix termination kit - High Rise Ventilator - EFT2 x Speed Controller - REB12 x PIR Sensor - PIR21 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3552 x QPTW 250C Acoustic Twin Fan with Controller1 x Elta Wall Cowl SWC56/631 x UB47- Universal Insulated Terminal1 x GRA-100 External Grill by S&P1 x Elta Wall Cowl SWC35/401 x Multi Input Run On Timer - 0 - 20min - CFCU1 x REU 1.5amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x Transformer 5 Speed Controller - ATC1-4TK2 x Transformer speed controller - ATC1 - 1.5 Amps1 x Vent Axia Silent 100T (TIMER)2 x KMBI 315 Connector rectangular/circular to install on the discharge of CMT1 x Elta Louvre Shutter - 400mm1 x SAVE VSR 300 heat recovery unit1 x Elta Wall Cowl SWC45/502 x Vent Axia ACM 150 inline mixed flow duct fan2 x Vent Axia ACM 200 inline mixed flow duct fan1 x Elta 6 Amp Electronic single phase speed controller with TK2 x Elta 3 Amp Electronic single phase speed controller with TK2 x Speed Controller - REB51 x MV-B Dual Switch for use with Helios HQW plate fans,2 x Contactor Interface Station - CI91 x AIRVENT speed control - AIR4019611 x PIR Sensor - PIR42 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan2 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Speed controller with Reverse - REB-1R2 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x CS2 Current Switch2 x Single phase speed controller by auto-transformer - RMB 1.5 Amp2 x Remote Timer Control - 13511 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x Airvent ceiling fan controller2 x Silent 100 Window Kit - windowS1 x Multiflow SMB550/4-1AC2 x Transformer (silent) speed controller - RE 5.0 Amp1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Speed Controller - REB2.5-N1 x DDMP 12-12 3F 1810W M6A4 DG01 x Elta Variable Speed Drive IP66 - 4.0KW1 x Mini Diffuser - 100mm1 x Transformer 5 Speed Controller - ATC1-2TK1 x Helios TSW 3 Amp Transformer speed controller1 x RDS 11 Helios Transformer Controller With Motor Protection2 x Helios TSW 1.5 Amp Transformer speed controller1 x DEF-140T Inlet Guard for the CBT-100N2 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven2 x Isolator Switch - ISOSW3 x Speed Controller - REB1-N2 x MTP 10, 10K, Speed control2 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Temperature Fan Speed Controller - ATCP4-WMS1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x 7 Day Programmable TIMECLOCK1 x CBS-60 Outlet Flange for CSB/CBT-601 x TG-K3/NTC10-01 - Duct temperature sensor1 x Helios HQW-200/4 - IP551 x Transformer (silent) speed controller - RE 1.5 Amp1 x Speed Controller - REB101 x RDH FLEX-SQUARE - ADH/RDH 04502 x Electronic extractor fan speed controller - FSC 1.51 x MWS 1.5 – Transformer Controller With Motor Protection2 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x TUNE-R-200-3-M1 - Control Damper1 x Skyflow SSR Horizontal Roof Cowl SSR31/35B1 x TD Mixvent 800/200 EEXEIIT31 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS1 x Helios HQW-250/4 - IP551 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x VTR 300 STD Filter Kit1 x Speed Controller - REB81 x ENV 100 12v transformer SELV1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x CBT-100N Centrifugal1 x Elta - Room Sensor - Temp/Humid/C021 x GXC6EC - High Performance Extract Fan1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x TUNE-R-200-3-M4 - Control Damper1 x CBM 9-9 550w 4P VR (Open Motor)1 x Transformer Speed Control - RTRE- 1.5Amp1 x Remote controller FLEX - for VEKO INT1 x Helios TSW 7.5 Amp Transformer speed controller1 x Helios TSW 0.3Amp Compact Transformer speed controller1 x Transformer 5 Speed Controller - ATC1-8TK1 x Push Timer Switch - ZA42 x MWS 3 – Transformer Controller With Motor Protection1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp2 x WS - Reversing Switch from Helios Fans1 x Transformer Speed Control - RTRE- 5.0Amp1 x Transformer Speed Control - RTRE- 7.0Amp