• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x Elta 6 Amp Electronic single phase speed controller with TK1 x EM30-24 Electro-Mechanical Control Panel1 x EC-Vent Room Unit4 x WS - Reversing Switch from Helios Fans3 x Single phase speed controller by auto-transformer - RMB 8.0 Amp4 x Systemair Save Connect 2.0 Internet Module3 x Electronic extractor fan speed controller - FSC 1.51 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)4 x MWS 1.5 – Transformer Controller With Motor Protection2 x Elta 3 Amp Electronic single phase speed controller with TK1 x Elta ACO Panel 149-ACO18B1 x Easy-fix termination kit - High Rise Ventilator - EFT2 x Transformer Speed Control - RTRE- 12.0Amp5 x Transformer (silent) speed controller - RE 3.0 Amp2 x EC6H - Reversible Group Fan Electronic Controller1 x EM30-24 Control Panel Commissioning Service2 x Vent Axia T-Series Controller2 x Remote Timer Control - 13512 x Two Speed Switch - REGUL-21 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6302 x Transformer 5 Speed Controller - ATC1-12TK1 x Transformer 5 Speed Controller - ATC1-8TK2 x TG-K Duct temperature sensor1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT2 x Transformer Speed Control - RTRE- 1.5Amp1 x Helios HQW-630/4 - IP551 x Elta Wall Cowl SWC56/631 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x TG-K3/NTC10-01 - Duct temperature sensor2 x Transformer 5 Speed Controller - ATC1-2TK1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans4 x Helios HQW-200/4 - IP551 x REE-1 Electronic Speed Controller1 x Speed Controller - REB1-N1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x CBS-60 Outlet Flange for CSB/CBT-601 x Elta Wall Cowl SWC35/401 x Contactor Interface Station - CI91 x Elta Variable Speed Drive IP66 - 0.75KW1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan2 x DEF-140T Inlet Guard for the CBT-100N2 x Skyflow SSR Horizontal Roof Cowl SSR31/35B1 x Transformer (silent) speed controller - RE 1.5 Amp1 x Airvent ceiling fan controller2 x SG-200 Fan Guard for the HQW 2001 x CBA-60 Inlet Flange for CBT-601 x EBM-Papst D4E225-BC01-17 Double inlet2 x Vent Axia Silent 100T (TIMER)1 x Transformer (silent) speed controller - RE 5.0 Amp1 x BEAS-control module1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp