• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x Mini Diffuser - 100mm2 x TUNE-R-250-1-M2 - Control Damper1 x Compact SCD450/4-1AC1 x Contactor Interface Station - CI91 x Elta Standard Ambient Flexible Connector - 560mm1 x VTR 300 STD Filter Kit1 x DDMP 10-08 3F 2210W M6A4 DG02 x TUNE-R-100-2-M1 - Control Damper2 x BDS 800 RA b/d shutter1 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR1 x Electrostatic Precipitator - 1H x 3W1 x Silentub - STUB 1001 x CMT/4-315/130-4KW - Single inlet centrifugal fan direct driven1 x AXC TP - 100mm Plastic Centrifugal Inline Fan1 x Duct Termination with Mesh - 355mm1 x SAVE VSR 300 heat recovery unit2 x SPI-100 C Iris damper1 x CO2 Room Sensor - CO2-R1 x CMT/4-250-100 1.1KW - Single inlet centrifugal fan direct driven ( LG-90)1 x Helios RR-250-C Centrifugal inline fan2 x Duct Termination with Mesh - 560mm2 x TD EVO-100 PF ECOWATT - Environmentally Friendly Energy Efficient Inline Fan1 x Elta Variable Speed Drive IP66 - 0.75KW1 x Elta - Room Sensor - Temp/Humid/C022 x HIMF - Mixed Flow Fan 125mm Inline Fan1 x ELTA - Three Phase Transformer 3amps3 x HIMF - Mixed Flow Fan 100mm Inline Fan1 x Silent 300 CZ Design PLUS Extractor Fan1 x Transformer Speed Control - RTRE- 5.0Amp1 x QPTW 250C Acoustic Twin Fan with Controller1 x Helios ZNE Electronic Fan Overrun Timer1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)1 x EC Trickle and boost module - IP561 x RUCK MTP 20, 10K, Speed control1 x Helios PA10 Speed Potentiometer1 x TUNE-R-200-3-M5 - Control Damper1 x CMT-2 120/50 - 0,09Kw - LG270 Single inlet centrifugal fan direct driven2 x Elta SCP400/4-1AC - IP551 x RDH Flange - 04501 x 100mm Round Connector with Damper1 x Flanged Damper 019-0560-STD1 x TUNE-R-250-1-M1 - Control Damper1 x KAD-225-F400 Rectangle Flexible Connector1 x RDH Flange - 03151 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt C VR1 x EX 140A-2 (Three Phase) Centrifugal Fan (ATEX)1 x Biflow SB315-CON4-3 - High Temperature Bifurcated Fan1 x Universal Pipe Fixing Clip1 x PM230-TF, AC 230V Damper Actuator, Spring Return, 2 x SPDT, 72C Thermal Fuse
Reviews
Airvent Ceiling Sweep Fan - 36 inch - 444122
Airvent Ceiling Sweep Fan - 36 inch - 444122
£ 59.84

Fitted 2 Of These Excellent Fans in a Community Club to shif...