• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x Transformer (silent) speed controller - RE 1.5 Amp2 x Helios HQW-200/4 - IP551 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven2 x Speed Controller - REB54 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Airvent ceiling fan controller2 x Elta Variable Speed Drive IP66 - 0.75KW2 x REB-CVF 0-10v Controller2 x TG-R room temperature sensor1 x EC6H - Reversible Group Fan Electronic Controller1 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS2 x SG-200 Fan Guard for the HQW 2001 x Remote Timer Control - 13512 x Transformer (silent) speed controller - RE 3.0 Amp1 x Quietflow SQS400-1ECL - Centrifugal Box Fan2 x Electronic extractor fan speed controller - FSC 1.51 x Isolator Switch - EFF-ISO2 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)3 x Elta Variable Speed Drive IP66 - 2.2KW3 x Speed Controller - REB101 x Vent Axia T-Series Controller2 x Helios PU10 Speed Potentiometer (Flush Mounted)1 x TUNE-R-200-3-M1 - Control Damper5 x MTP 10, 10K, Speed control2 x Transformer Speed Control - RTRE- 12.0Amp2 x Silent 100 Window Kit - windowS4 x Helios HQW-315/4 - IP553 x Speed Controller - REB1-N1 x Elta Wall Cowl SWC56/634 x Vent Axia Silent 100T (TIMER)2 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)4 x Helios HQW-250/4 - IP551 x GRA-100 External Grill by S&P1 x Elta Louvre Shutter - 400mm3 x PIR Sensor - PIR21 x TD Mixvent 800/200 EEXEIIT31 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE2 x Two Speed Switch - REGUL-21 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)2 x RDH FLEX-SQUARE - ADH/RDH 04501 x Transformer (silent) speed controller - RE 5.0 Amp2 x DDMP 10-08 3F 2210W M6A4 DG02 x QPTW 250C Acoustic Twin Fan with Controller1 x Transformer 5 Speed Controller - ATC1-4TK1 x Transformer speed controller - ATC1 - 1.5 Amps1 x ELM 18 EX Flexible Cuff for ERM 183 x UB47- Universal Insulated Terminal2 x Helios TSW 1.5 Amp Transformer speed controller1 x Elta Wall Cowl SWC25/312 x RDS 11 Helios Transformer Controller With Motor Protection2 x Biflow SB400-CON2-3 - High Temperature Bifurcated Fan1 x EBM-Papst D4E225-BC01-17 Double inlet1 x CBM 9-9 550w 4P VR (Open Motor)3 x PIR Sensor - PIR41 x Elta Wall Cowl SWC35/403 x Elta 6 Amp Electronic single phase speed controller.1 x LFBR 315 G4 - Helios Inline Filter Box - 315mm2 x Transformer Speed Control - RTRE- 7.0Amp1 x Compact SCD450/4-1AC2 x Elta - Room Sensor - Temp/Humid/C022 x MTS10- extractor fan 3 step switch1 x Speed controller with Reverse - REB-1R1 x Transformer 5 Speed Controller - ATC1-2TK1 x TD EVO-100 PF ECOWATT - Environmentally Friendly Energy Efficient Inline Fan2 x Transformer Speed Control - RTRE- 1.5Amp1 x Egg Crate Grille with G2 Dust panel filter 1 inch- 300x3001 x CBA-60 Inlet Flange for CBT-601 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x FAST-TRACK RANGE 75mm - Click Ring (1 bag of 10)1 x REE-2 Electronic Speed Controller1 x DDMP 12-12 3F 1810W M6A4 DG01 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Quietflow SQS100-1ECL - Centrifugal Box Fan1 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Jet Cowl - 315mm1 x TG-K Duct temperature sensor1 x Mini Diffuser - 100mm1 x RDS 7 Helios Transformer Controller With Motor Protection
Reviews
EM 250-E2M 01- Etamaster-250
EM 250-E2M 01- Etamaster-250
£ 128.80

Really well made but comes with no speed controler? ?and can...