• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x Vent Axia ACM 100 inline mixed flow duct fan1 x Run On Timer - 5s - 4hrs - RT5A2 x Remote Timer Control - 13513 x Push Timer Switch - ZA43 x Isolator Switch - ISOSW1 x Helios ZNE Electronic Fan Overrun Timer1 x Time Delay Unit - DT20B3 x Multi Input Run On Timer - 0 - 20min - CFCU1 x Multiflow SMB550/4-1AC1 x 7 Day Programmable TIMECLOCK1 x Remote controller FLEX - for VEKO INT1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Helios TSW 7.5 Amp Transformer speed controller1 x NKS-D swirl diffuser v-300 x 300mm1 x Balance S Diffuser - NO RING - 125mm1 x Circular Ceiling Diffuser - TST 1251 x Circular Ceiling Diffuser - TST 1001 x PCA Diffuser - PCA-3151 x Curved Blade Grille 600x600 (2way blow)1 x JSR 200 Painted RAL50181 x Circular Ceiling Diffuser - TST 2001 x Round ceiling diffuser 400mm1 x Circular Ceiling Diffuser - TST 1601 x Round ceiling diffuser 200mm1 x Balance S Diffuser - NO RING - 100mm1 x Round ceiling diffuser 300mm1 x PCA Diffuser - PCA-2501 x Round ceiling diffuser 350mm1 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Transformer 5 Speed Controller - ATC1-4TK1 x Helios TSW MCB Amp Transformer speed controller2 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)2 x Elta 3 Amp Electronic single phase speed controller with TK1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x Helios HQW-630/4 - IP551 x ACO8AC/EC AutoChangeover panel1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x TTC-2000 Three phase electric heater controller1 x REB-CVF 0-10v Controller1 x Elta ACO Panel 149-ACO14E2 x Transformer 5 Speed Controller - ATC1-12TK1 x TG-K Duct temperature sensor2 x Vent Axia ACM 150 inline mixed flow duct fan1 x Vent Axia ACM 125 inline mixed flow duct fan1 x Systemair Save Connect 2.0 Internet Module1 x DEF-140T Inlet Guard for the CBT-100N1 x Elta 6 Amp Electronic single phase speed controller with TK1 x TG-K3/NTC10-01 - Duct temperature sensor1 x CBS-60 Outlet Flange for CSB/CBT-601 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x CS2 Current Switch1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Transformer (silent) speed controller - RE 1.5 Amp1 x Electronic extractor fan speed controller - FSC 1.51 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x Transformer (silent) speed controller - RE 5.0 Amp1 x Vent Axia ACM 200 inline mixed flow duct fan
Reviews
Duct Mounted Inline Filter - EU4
Duct Mounted Inline Filter - EU4
£ 44.99

Well made and robust, but it was not use for my application ...