• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x TG-K3/NTC10-01 - Duct temperature sensor1 x EC-Vent control board1 x EM30-24 Electro-Mechanical Control Panel1 x Elta 3 Amp Electronic single phase speed controller with TK1 x BEAS-control module5 x MWS 1.5 – Transformer Controller With Motor Protection1 x ACO 149-ACO1/EDV1 x Elta 6 Amp Electronic single phase speed controller with TK1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven5 x WS - Reversing Switch from Helios Fans2 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted2 x Transformer (silent) speed controller - RE 1.5 Amp1 x Single phase speed controller by auto-transformer - RMB 8.0 Amp2 x EC6H - Reversible Group Fan Electronic Controller1 x Helios HQW-630/4 - IP551 x EC-Vent Room Unit1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection2 x Elta ACO Panel 149-ACO18B2 x Systemair Save Connect 2.0 Internet Module1 x Vent Axia T-Series Controller1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6304 x Helios HQW-200/4 - IP551 x Transformer 5 Speed Controller - ATC1-12TK1 x REE-1 Electronic Speed Controller1 x REB-CVF 0-10v Controller1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x MEV Spider Wireless boost Switch - MEV-SWH-W1 x Transformer Speed Control - RTRE- 12.0Amp2 x Airvent ceiling fan controller1 x Electronic extractor fan speed controller - FSC 1.51 x TUNE-R-200-3-M1 - Control Damper1 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS2 x Remote Timer Control - 13511 x Single phase speed controller by auto-transformer - RMB 10.0 Amp3 x Vent Axia Silent 100T (TIMER)1 x Easy-fix termination kit - High Rise Ventilator - EFT3 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans4 x Transformer (silent) speed controller - RE 3.0 Amp2 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x EBM-Papst D4E225-BC01-17 Double inlet2 x PIR Sensor - PIR42 x Multiflow SMB550/4-1AC1 x Speed Controller - REB51 x FAST-TRACK RANGE 75mm - Click Ring (1 bag of 10)2 x Helios HQW-250/4 - IP551 x MTP 10, 10K, Speed control1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x Elta Variable Speed Drive IP66 - 0.75KW1 x SG-200 Fan Guard for the HQW 2001 x PIR Sensor - PIR21 x Speed Controller - REB101 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR1 x CBS-60 Outlet Flange for CSB/CBT-601 x RDH FLEX-SQUARE - ADH/RDH 04501 x TD Mixvent 800/200 EEXEIIT31 x DDMP 12-12 3F 1810W M6A4 DG01 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Helios TSW 7.5 Amp Transformer speed controller1 x Helios TSW 1.5 Amp Transformer speed controller1 x Two Speed Switch - REGUL-2
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 11.49

Look good, works well, except the shaft of the lanellae cuts...