• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x Single phase speed controller by auto-transformer - RMB 8.0 Amp1 x Elta 6 Amp Electronic single phase speed controller with TK3 x MWS 1.5 – Transformer Controller With Motor Protection2 x WS - Reversing Switch from Helios Fans1 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT4 x Helios HQW-630/4 - IP556 x Transformer (silent) speed controller - RE 3.0 Amp1 x Helios HQW-200/2 - IP553 x Electronic extractor fan speed controller - FSC 1.51 x BEAS-control module3 x Helios HQW-200/4 - IP551 x Systemair Save Connect 2.0 Internet Module1 x Speed Controller - REB1-N3 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Remote Timer Control - 13511 x Envirovent G4 Filter - SL-G4/F73 x Vent Axia Silent 100T (TIMER)2 x PIR Sensor - PIR22 x EC6H - Reversible Group Fan Electronic Controller1 x Skyflow SSR Horizontal Roof Cowl SSR31/35B2 x TG-K3/NTC10-01 - Duct temperature sensor1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT3 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)2 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS1 x Speed Controller - REB51 x MTP 10, 10K, Speed control2 x TUNE-R-200-3-M1 - Control Damper1 x REE-1 Electronic Speed Controller1 x EBM-Papst D4E225-BC01-17 Double inlet2 x RDH FLEX-SQUARE - ADH/RDH 04501 x Multiflow SMB550/4-1AC2 x Transformer Speed Control - RTRE- 12.0Amp1 x Commercial Single or 3 phase Fan Reversing Switch - RS12 x Elta Variable Speed Drive IP66 - 0.75KW1 x DEF-140T Inlet Guard for the CBT-100N1 x MEV Spider Wireless boost Switch - MEV-SWH-W1 x PIR Sensor - PIR41 x Speed Controller - REB102 x Vent Axia T-Series Controller1 x Transformer Speed Control - RTRE- 7.0Amp1 x Helios TSW 1.5 Amp Transformer speed controller1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x CBS-60 Outlet Flange for CSB/CBT-601 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Two Speed Switch - REGUL-21 x MTS10- extractor fan 3 step switch1 x Helios PU10 Speed Potentiometer (Flush Mounted)1 x Transformer (silent) speed controller - RE 1.5 Amp1 x UB47- Universal Insulated Terminal1 x Isolator Switch - EFF-ISO2 x Airvent ceiling fan controller1 x Helios HQW-250/4 - IP551 x DDMP 10-08 3F 2210W M6A4 DG01 x REU 7amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x Isolator Switch - ISOSW1 x TG-R room temperature sensor
Reviews
TD-SILENT 350/125
TD-SILENT 350/125
£ 178.68

Excellent low noise fan, I've got one unit running years and...