• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

3 x Isolator Switch - ISOSW2 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x MWS 3 – Transformer Controller With Motor Protection1 x ACO8AC/EC AutoChangeover panel1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Elta ACO Panel 149-ACO14E4 x Elta 6 Amp Electronic single phase speed controller with TK1 x EC-Vent control board1 x CS2 Current Switch3 x Elta 3 Amp Electronic single phase speed controller with TK4 x Single phase speed controller by auto-transformer - RMB 8.0 Amp2 x CONTROL ECOWATT - Basic1 x ACO 149-ACO1/EDV1 x EM30-24 Electro-Mechanical Control Panel3 x COM-31 x TG-K3/NTC10-01 - Duct temperature sensor4 x WS - Reversing Switch from Helios Fans1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection3 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x EC-Vent Room Unit1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x Elta ACO Panel 149-ACO18B1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x Electronic extractor fan speed controller - FSC 1.52 x EC6H - Reversible Group Fan Electronic Controller3 x MWS 1.5 – Transformer Controller With Motor Protection1 x Two Speed Switch - REGUL-21 x TG-K Duct temperature sensor1 x EM30-24 Control Panel Commissioning Service2 x Helios HQW-200/2 - IP552 x Envirovent G4 Filter - SL-G4/F72 x Transformer 5 Speed Controller - ATC1-12TK1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5002 x BEAS-control module1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x CBS-60 Outlet Flange for CSB/CBT-601 x Vent Axia T-Series Controller2 x Transformer (silent) speed controller - RE 1.5 Amp1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Transformer (silent) speed controller - RE 3.0 Amp2 x Helios HQW-200/4 - IP551 x Helios HQW-630/4 - IP551 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted1 x RDS 7 Helios Transformer Controller With Motor Protection1 x DEF-140T Inlet Guard for the CBT-100N1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Vent Axia Silent 100T (TIMER)1 x TUNE-R-200-3-M1 - Control Damper1 x Elta Variable Speed Drive IP66 - 0.75KW
Reviews
Transformer (silent) speed controller - RE 1.5 Amp
Transformer (silent) speed controller - RE 1.5 Amp
£ 132.29

Incredible, Perfect, Silent and Fast delivery ! Thanks "Just...