• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

3 x Isolator Switch - ISOSW1 x Helios ZNE Electronic Fan Overrun Timer1 x Elta 3 Amp Electronic single phase speed controller with TK1 x Time Delay Unit - DT20B1 x 7 Day Programmable TIMECLOCK3 x Multi Input Run On Timer - 0 - 20min - CFCU2 x CS2 Current Switch2 x Elta 6 Amp Electronic single phase speed controller with TK1 x TTC-2000 Three phase electric heater controller1 x ACO8AC/EC AutoChangeover panel1 x ACOAS/ AC/EC Auto Changeover 8Amp2 x Single phase speed controller by auto-transformer - RMB 8.0 Amp2 x Single phase speed controller by auto-transformer - RMB 1.5 Amp2 x TG-K Duct temperature sensor1 x Helios HQW-200/2 - IP551 x BEAS-control module1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Elta ACO Panel 149-ACO14E1 x Transformer 5 Speed Controller - ATC1-12TK3 x Systemair Save Connect 2.0 Internet Module3 x TG-K3/NTC10-01 - Duct temperature sensor1 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted1 x CONTROL ECOWATT - Basic1 x EM30-24 Electro-Mechanical Control Panel1 x EC-Vent control board1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x MWS 1.5 – Transformer Controller With Motor Protection2 x Elta Variable Speed Drive IP66 - 0.75KW1 x ACO 149-ACO1/EDV3 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan3 x EC6H - Reversible Group Fan Electronic Controller1 x Elta ACO Panel 149-ACO18B1 x Speed Controller - REB101 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x WS - Reversing Switch from Helios Fans1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x RDH FLEX-SQUARE - ADH/RDH 04502 x Vent Axia Silent 100T (TIMER)2 x Isolator Switch - EFF-ISO1 x CBS-60 Outlet Flange for CSB/CBT-602 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR3 x Transformer (silent) speed controller - RE 3.0 Amp1 x Airvent ceiling fan controller1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT1 x DEF-140T Inlet Guard for the CBT-100N2 x Transformer Speed Control - RTRE- 7.0Amp1 x CBA-60 Inlet Flange for CBT-601 x PIR Sensor - PIR21 x 220x90mm Insulated Rectangular Horizontal 90° Bend2 x Electronic extractor fan speed controller - FSC 1.51 x PIR Sensor - PIR41 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x Transformer Speed Control - RTRE- 12.0Amp1 x Multiflow SMB550/4-1AC1 x Speed Controller - REB81 x Speed Controller - REB51 x Helios HQW-200/4 - IP552 x SG-200 Fan Guard for the HQW 2001 x AXC TP - 150mm Plastic Centrifugal Inline Fan2 x Vent Axia T-Series Controller1 x CMT-2 120/50 - 0,09Kw - LG270 Single inlet centrifugal fan direct driven1 x Helios PU10 Speed Potentiometer (Flush Mounted)1 x Elta Variable Speed Drive IP66 - 2.2KW1 x CBT-100N Centrifugal1 x CFI In-line 425 - Carbon Filter1 x 220x90mm Insulated Rectangular Horizontal 45° Bend1 x Speed Controller - REB11 x 220x90mm Insulated Rectangular Vertical 45° Bend1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x CBM 9-9 550w 4P VR (Open Motor)1 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x CBA-100 Inlet Flange for CBT-1001 x HIMF - Mixed Flow Fan 100mm Inline Fan1 x REB-CVF 0-10v Controller1 x 220x90mm Insulated Rectangular Vertical 90° Bend1 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Easy-fix termination kit - High Rise Ventilator - EFT1 x Transformer Speed Control - RTRE- 1.5Amp1 x RD35S-4DW.6W.3L - 122297 (Three Phase)1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 11.49

Look good, works well, except the shaft of the lanellae cuts...