• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x Single phase speed controller by auto-transformer - RMB 8.0 Amp4 x MWS 1.5 – Transformer Controller With Motor Protection2 x WS - Reversing Switch from Helios Fans1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT2 x BEAS-control module1 x EM30-24 Control Panel Commissioning Service3 x EC6H - Reversible Group Fan Electronic Controller3 x Electronic extractor fan speed controller - FSC 1.52 x Helios HQW-200/2 - IP552 x Envirovent G4 Filter - SL-G4/F71 x CS2 Current Switch2 x Vent Axia T-Series Controller3 x Transformer Speed Control - RTRE- 12.0Amp5 x Transformer (silent) speed controller - RE 3.0 Amp2 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted2 x Helios HQW-630/4 - IP553 x TG-K3/NTC10-01 - Duct temperature sensor2 x Remote Timer Control - 13511 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven4 x Helios HQW-200/4 - IP551 x Transformer (silent) speed controller - RE 1.5 Amp2 x Commercial Single or 3 phase Fan Reversing Switch - RS12 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Two Speed Switch - REGUL-22 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS2 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans3 x Airvent ceiling fan controller1 x CBS-60 Outlet Flange for CSB/CBT-602 x TG-R room temperature sensor2 x Helios PU10 Speed Potentiometer (Flush Mounted)4 x Helios HQW-315/4 - IP551 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE3 x Transformer Speed Control - RTRE- 7.0Amp2 x MTP 10, 10K, Speed control3 x Vent Axia Silent 100T (TIMER)2 x Elta Variable Speed Drive IP66 - 0.75KW2 x Transformer (silent) speed controller - RE 5.0 Amp3 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)3 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR4 x SG-200 Fan Guard for the HQW 2001 x Isolator Switch - EFF-ISO2 x Speed Controller - REB52 x Vent Axia ACM 200 inline mixed flow duct fan1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)2 x Transformer Speed Control - RTRE- 1.5Amp2 x Speed Controller - REB101 x CBM 9-9 550w 4P VR (Open Motor)2 x MTS10- extractor fan 3 step switch1 x RDH FLEX-SQUARE - ADH/RDH 04502 x Elta 6 Amp Electronic single phase speed controller.3 x QPTW 250C Acoustic Twin Fan with Controller2 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x 7 Day Programmable TIMECLOCK1 x Speed Controller - REB1-N1 x TD Mixvent 800/200 EEXEIIT32 x EBM-Papst D4E225-BC01-17 Double inlet1 x Isolator Switch - ISOSW1 x CBA-60 Inlet Flange for CBT-601 x Helios HQW-250/4 - IP551 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR2 x Elta Variable Speed Drive IP66 - 2.2KW2 x PIR Sensor - PIR21 x Transformer 5 Speed Controller - ATC1-2TK2 x RDS 11 Helios Transformer Controller With Motor Protection1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x REE-2 Electronic Speed Controller
Reviews
Transformer (silent) speed controller - RE 1.5 Amp
Transformer (silent) speed controller - RE 1.5 Amp
£ 132.29

Unbelievable! With TDmixvent500: noise reduction minimum 50%...