• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x DDMP 09-09 3F 2130W M6A4 DG02 x Speed Controller - REB1-N2 x SG-200 Fan Guard for the HQW 2001 x Speed Controller - REB101 x CBA-60 Inlet Flange for CBT-601 x EBM-Papst D4E225-BC01-17 Double inlet1 x Elta Variable Speed Drive IP66 - 2.2KW3 x Transformer Speed Control - RTRE- 1.5Amp1 x Helios HQW-315/4 - IP552 x LFBR 160 G4 - Helios Inline Filter Box - 160mm1 x Vent Axia Silent 100T (TIMER)2 x KBA- Inlet Mounting 3551 x Transformer Speed Control - RTRE- 7.0Amp1 x WS - Reversing Switch from Helios Fans1 x FFR 355 Filter Cassette2 x KBA- inlet mounting flange for CRMT 2251 x QPTW 250C Acoustic Twin Fan with Controller1 x TD Mixvent 800/200 EEXEIIT32 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x FRQ5-10A Inverter Speed controller1 x Helios TSW 1.5 Amp Transformer speed controller5 x DDMP 12-12 3F 1810W M6A4 DG02 x DDMP 09/09 Mounting Flange2 x Airvent ceiling fan controller1 x RD35S-4DW.6W.3L - 122297 (Three Phase)2 x Speed Controller - REB81 x Transformer Speed Control - RTRE- 5.0Amp1 x ACO8AC/EC AutoChangeover panel1 x MTS10- extractor fan 3 step switch1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF450/4-1AC - Single Phase1 x ELM 18 EX Flexible Cuff for ERM 181 x VTR 300 STD Filter Kit1 x Helios HQW-250/4 - IP551 x CMT/4-280-115 2.2KW - Single inlet centrifugal fan direct driven ( LG-90)1 x DDMP 10-08 3F 2210W M6A4 DG02 x UB47- Universal Insulated Terminal1 x KAD-355-F400 Rectangle Flexible Connector1 x ENV 100 12v transformer SELV1 x PIR Sensor - PIR42 x Speed Controller - REB11 x Transformer (silent) speed controller - RE 3.0 Amp2 x Elta 6 Amp Electronic single phase speed controller.1 x TG-K Duct temperature sensor1 x HIMF - Mixed Flow Fan 125mm Inline Fan2 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x CBT-100N Centrifugal1 x Elta - Room Sensor - Temp/Humid/C023 x REU 7amp Speed control - Two Speed Five-Step Transformer - Trickle and Boost1 x DA9/9-NT2 x Duct Termination with Mesh - 450mm1 x SAVE VSR 300 heat recovery unit1 x TUNE-R-315-3-M4 - Control Damper1 x CMT/4-315/130-4KW - Single inlet centrifugal fan direct driven1 x Compact SCD450/4-1AC1 x CMT/4-250-100 1.1KW - Single inlet centrifugal fan direct driven ( LG-90)1 x CBM Low Pressure Centrifugal Fan - CBM 12/12 6 Pole 736watt CVR1 x KBA- inlet mounting flange for CRMT 2501 x Comefri - TLZ 560 R - High Performance Scroll Fan1 x Potentiometer EGH 01 - for DDMP Fans
Reviews
Vectaire Elegance Low Energy DMEV Fan Range
Vectaire Elegance Low Energy DMEV Fan Range
£ 131.69

I've had 2 of these fans for 4 years now, and they are great...