• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x MWS 3 – Transformer Controller With Motor Protection2 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x Isolator Switch - ISOSW1 x CS2 Current Switch3 x Single phase speed controller by auto-transformer - RMB 8.0 Amp1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x CONTROL ECOWATT - Basic3 x Elta 6 Amp Electronic single phase speed controller with TK1 x ACO 149-ACO1/EDV1 x EM30-24 Electro-Mechanical Control Panel4 x MWS 1.5 – Transformer Controller With Motor Protection3 x WS - Reversing Switch from Helios Fans1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x Elta ACO Panel 149-ACO18B1 x EC-Vent Room Unit2 x BEAS-control module2 x Systemair Save Connect 2.0 Internet Module3 x Electronic extractor fan speed controller - FSC 1.53 x EC6H - Reversible Group Fan Electronic Controller2 x Helios HQW-200/2 - IP552 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted1 x EM30-24 Control Panel Commissioning Service1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5002 x Vent Axia T-Series Controller2 x Transformer Speed Control - RTRE- 12.0Amp2 x Helios HQW-630/4 - IP552 x Transformer 5 Speed Controller - ATC1-12TK1 x TG-K Duct temperature sensor1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6302 x TG-K3/NTC10-01 - Duct temperature sensor5 x Transformer (silent) speed controller - RE 3.0 Amp1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Vent Axia ACM 125 inline mixed flow duct fan1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Easy-fix termination kit - High Rise Ventilator - EFT2 x REE-1 Electronic Speed Controller4 x Helios HQW-200/4 - IP551 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Two Speed Switch - REGUL-22 x Remote Timer Control - 13511 x Transformer (silent) speed controller - RE 1.5 Amp1 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3552 x Airvent ceiling fan controller1 x Transformer Speed Control - RTRE- 1.5Amp1 x SG-200 Fan Guard for the HQW 2001 x RDS 7 Helios Transformer Controller With Motor Protection1 x CBS-60 Outlet Flange for CSB/CBT-601 x Elta Variable Speed Drive IP66 - 0.75KW1 x Vent Axia Silent 100T (TIMER)1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x Helios PU10 Speed Potentiometer (Flush Mounted)1 x TG-R room temperature sensor1 x Transformer 5 Speed Controller - ATC1-2TK1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans