• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x Single phase speed controller by auto-transformer - RMB 8.0 Amp2 x MWS 1.5 – Transformer Controller With Motor Protection1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x Systemair Save Connect 2.0 Internet Module1 x EC-Vent Room Unit1 x Envirovent G4 Filter - SL-G4/F72 x Commercial Single or 3 phase Fan Reversing Switch - RS12 x Speed Controller - REB52 x WS - Reversing Switch from Helios Fans1 x EC6H - Reversible Group Fan Electronic Controller1 x KKS 100 silencer-section - For use with the MUB 100 size Fans.2 x TG-R room temperature sensor1 x EM30-24 Control Panel Commissioning Service1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6302 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x Helios HQW-630/4 - IP551 x Multiflow SMB550/4-1AC1 x Speed Controller - REB102 x Isolator Switch - EFF-ISO1 x Transformer Speed Control - RTRE- 7.0Amp2 x Helios PU10 Speed Potentiometer (Flush Mounted)1 x Easy-fix termination kit - High Rise Ventilator - EFT3 x Transformer (silent) speed controller - RE 3.0 Amp1 x Helios HQW-315/4 - IP553 x Vent Axia T-Series Controller5 x Elta Variable Speed Drive IP66 - 0.75KW2 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)2 x Electronic extractor fan speed controller - FSC 1.51 x Helios HQW-200/4 - IP551 x CBA-60 Inlet Flange for CBT-601 x REB-CVF 0-10v Controller1 x TUNE-R-200-3-M1 - Control Damper1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)2 x Vent Axia ACM 200 inline mixed flow duct fan2 x RDH FLEX-SQUARE - ADH/RDH 04505 x Vent Axia Silent 100T (TIMER)1 x Remote Timer Control - 13512 x MTP 10, 10K, Speed control4 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR3 x PIR Sensor - PIR21 x EBM-Papst D4E225-BC01-17 Double inlet2 x Transformer Speed Control - RTRE- 1.5Amp1 x Transformer (silent) speed controller - RE 5.0 Amp1 x Speed Controller - REB1-N1 x Elta Variable Speed Drive IP66 - 2.2KW1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x REE-1 Electronic Speed Controller1 x MTS10- extractor fan 3 step switch1 x Speed controller with Reverse - REB-1R1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x RDS 11 Helios Transformer Controller With Motor Protection1 x TD Mixvent 800/200 EEXEIIT31 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x REE-2 Electronic Speed Controller1 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS1 x QPTW 250C Acoustic Twin Fan with Controller1 x DDMP 12-12 3F 1810W M6A4 DG01 x PIR Sensor - PIR41 x Helios HQW-250/4 - IP551 x Speed Controller - REB11 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Two Speed Switch - REGUL-21 x Transformer Speed Control - RTRE- 12.0Amp1 x SG-200 Fan Guard for the HQW 2001 x Elta Wall Cowl SWC56/632 x Airvent ceiling fan controller1 x Helios TSW 1.5 Amp Transformer speed controller1 x Elta 10 Amp Electronic single phase speed controller.1 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan