• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x Elta 6 Amp Electronic single phase speed controller with TK1 x TG-K Duct temperature sensor3 x WS - Reversing Switch from Helios Fans2 x Elta 3 Amp Electronic single phase speed controller with TK2 x TG-K3/NTC10-01 - Duct temperature sensor1 x Single phase speed controller by auto-transformer - RMB 8.0 Amp2 x MWS 1.5 – Transformer Controller With Motor Protection1 x EC6H - Reversible Group Fan Electronic Controller2 x Transformer (silent) speed controller - RE 1.5 Amp2 x Helios HQW-200/2 - IP551 x Elta 10 Amp Electronic single phase speed controller.1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT1 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Transformer Speed Control - RTRE- 12.0Amp1 x Envirovent G4 Filter - SL-G4/F71 x Single phase speed controller by auto-transformer - RMB 10.0 Amp2 x Two Speed Switch - REGUL-21 x CBS-60 Outlet Flange for CSB/CBT-604 x Helios HQW-200/4 - IP552 x Helios HQW-630/4 - IP552 x TUNE-R-200-3-M1 - Control Damper2 x Electronic extractor fan speed controller - FSC 1.51 x REE-1 Electronic Speed Controller1 x Transformer Speed Control - RTRE- 7.0Amp1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR3 x Transformer (silent) speed controller - RE 3.0 Amp2 x Speed Controller - REB102 x Skyflow SSR Horizontal Roof Cowl SSR31/35B1 x RDS 7 Helios Transformer Controller With Motor Protection1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans3 x Vent Axia Silent 100T (TIMER)1 x SG-200 Fan Guard for the HQW 2001 x Helios HQW-250/4 - IP551 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x Isolator Switch - ISOSW2 x EBM-Papst D4E225-BC01-17 Double inlet1 x MTP 10, 10K, Speed control2 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x MEV Spider Wireless boost Switch - MEV-SWH-W1 x Remote Timer Control - 13511 x Airvent ceiling fan controller1 x MV-B Dual Switch for use with Helios HQW plate fans,2 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Transformer 5 Speed Controller - ATC1-2TK1 x Helios TSW 1.5 Amp Transformer speed controller1 x PIR Sensor - PIR41 x Skyflow SSR Horizontal Roof Cowl SSR31/35BS1 x RDH FLEX-SQUARE - ADH/RDH 04502 x DDMP 12-12 3F 1810W M6A4 DG01 x Speed Controller - REB51 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR2 x TUNE-R-200-3-M4 - Control Damper1 x Multiflow SMB550/4-1AC2 x CBT-100N Centrifugal1 x Elta Variable Speed Drive IP66 - 0.75KW1 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)1 x Transformer (silent) speed controller - RE 5.0 Amp
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 11.49

Look good, works well, except the shaft of the lanellae cuts...