• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

2 x MWS 3 – Transformer Controller With Motor Protection2 x Isolator Switch - ISOSW2 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x CS2 Current Switch1 x ACO8AC/EC AutoChangeover panel1 x COM-33 x Elta 3 Amp Electronic single phase speed controller with TK1 x ACOAS/ AC/EC Auto Changeover 8Amp4 x Elta 6 Amp Electronic single phase speed controller with TK1 x Single phase speed controller by auto-transformer - RMB 8.0 Amp1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x CONTROL ECOWATT - Basic1 x EM30-24 Electro-Mechanical Control Panel1 x ACO 149-ACO1/EDV2 x MWS 1.5 – Transformer Controller With Motor Protection1 x BEAS-control module1 x TG-K Duct temperature sensor1 x WS - Reversing Switch from Helios Fans3 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Transformer (silent) speed controller - RE 1.5 Amp1 x Elta ACO Panel 149-ACO18B1 x Envirovent G4 Filter - SL-G4/F72 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted1 x EC6H - Reversible Group Fan Electronic Controller1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection2 x Systemair Save Connect 2.0 Internet Module1 x Helios HQW-200/2 - IP551 x EC-Vent Room Unit1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT2 x TG-K3/NTC10-01 - Duct temperature sensor2 x Transformer 5 Speed Controller - ATC1-12TK1 x EM30-24 Control Panel Commissioning Service1 x Vent Axia T-Series Controller1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Vent Axia ACM 125 inline mixed flow duct fan1 x QPTW 250C Acoustic Twin Fan with Controller1 x Speed Controller - REB1-N1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)2 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x TUNE-R-200-3-M1 - Control Damper1 x Silent 100 Window Kit - windowS3 x Transformer (silent) speed controller - RE 3.0 Amp2 x Transformer Speed Control - RTRE- 7.0Amp2 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)2 x PIR Sensor - PIR21 x Speed controller with Reverse - REB-1R3 x Helios HQW-200/4 - IP551 x Elta Variable Speed Drive IP66 - 2.2KW2 x Electronic extractor fan speed controller - FSC 1.51 x DEF-140T Inlet Guard for the CBT-100N1 x REE-1 Electronic Speed Controller1 x DDMP 10-08 3F 2210W M6A4 DG01 x Speed Controller - REB101 x VTR 300 STD Filter Kit1 x MEV300/160 Wireless Boost Switch - SWHWMEV1 x Elta Variable Speed Drive IP66 - 0.75KW1 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x CBS-60 Outlet Flange for CSB/CBT-601 x Two Speed Switch - REGUL-21 x CBA-60 Inlet Flange for CBT-601 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x CBT-100N Centrifugal1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT
BD9/9 centrifugal M4 0.35Kw
BD9/9 centrifugal M4 0.35Kw
£ 399.00 now £ 350.00
Reviews
Duct Mounted Inline Filter - EU4
Duct Mounted Inline Filter - EU4
£ 44.99

Well made and robust, but it was not use for my application ...