• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x DDMP 10-10 1F 1000W M6A2 DA53 x DDMP 12-09 1F 1800W M6A4 DA81 x CAD-COMPACT 900 ADVANCED N8 - MVHR unit2 x CBM Low Pressure Centrifugal Fan - CBM 12/12 6 Pole 736watt CVR1 x TD160-NT Mixvent - 100mm - TD160 Timer1 x RD31S-4DW.6Q.AL - 121303 (Three Phase)1 x RUCK MTP 20, 10K, Speed control1 x CBA-100 Inlet Flange for CBT-1001 x RD31S-4EW.6Q.AL - 122296 (Single Phase)1 x Spiral end cap - 80mm1 x SDD-U Anti Vibration Pads2 x RDH E0-0400 Mounting Feet (pair)1 x RDH Flange - 04002 x DDMP 12-12 1F 1800W M6A4 DA81 x VEKA INT 2000/15.0-L1 EKO2 x DDMP 10-08 1F 1000W M6A2 DA51 x Duct Termination with Mesh - 315mm2 x ELTA - Single Phase Transformer 2amps1 x ACOAS/ AC/EC Auto Changeover 8Amp2 x DDMP 10-08 FLANGE2 x VA 9/2 T - High Temp Axial Fan,1 x EX 140A-2 (Three Phase) Centrifugal Fan (ATEX)2 x 110 x 54mm Short Rectangular to Round Adaptor male1 x Kitchavent 2000 Odour control System - 18152521 x Vent Axia T-Series Wall Model TX9WL1 x RDH Flange - 02501 x Revolution SLCX ATEX Long Cased Axial Flow Fan SLCX500/4-3 Three Phase1 x CBM 9/7 4p 420W RE-VR1 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF315/4-1AC - Single Phase1 x Access Door for Circular Duct - 250 x 150 - SIZE 151 x Run On Timer - 5s - 4hrs - RT5A1 x CBM Low Pressure Centrifugal Fan - CBM 12/12 6 Pole 1100watt 6PT (Closed Motor)1 x Ducting T Piece Equal - 80mm1 x 125mm Round Connector with Damper1 x Round ceiling diffuser 200mm2 x CAD-COMPACT 500 ADVANCED N8 - MVHR unit1 x CBT-100N Centrifugal ATEX II 2G Exe II T31 x FRQ-10A V2 Inverter Speed controller1 x 220x90mm x 2m Insulated Rectangular Duct2 x DDMP 12-09 FLANGE1 x Helios ZNE Electronic Fan Overrun Timer2 x Potentiometer EGH 01 - for DDMP Fans1 x Spiral Ducting 1 meter - 80mm1 x Ducting 90 Degree Bend - 80mm1 x Spiral end cap - 150mm1 x Flanged Damper 019-0500-STD1 x Atex Inline Fan 180mm - ERM18EXE1 x Rectangular Airbrick Adaptor1 x Silentub - STUB 2001 x CBM Low Pressure Centrifugal Fan - CBM 9/9 4 Pole 550watt 3V (3-Speed)1 x Transformer Speed Control - RTRE- 3.0Amp1 x ELTA - Single Phase Transformer 16amps1 x AW 550 D6-2-EX Explosion Proof Axial Fan - ATEX