• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x 7 Day Programmable TIMECLOCK1 x ACO8AC/EC AutoChangeover panel1 x TG-K Duct temperature sensor1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x MWS 3 – Transformer Controller With Motor Protection3 x Elta 6 Amp Electronic single phase speed controller with TK1 x Elta ACO Panel 149-ACO14E1 x Single phase speed controller by auto-transformer - RMB 8.0 Amp1 x CONTROL ECOWATT - Basic1 x EC-Vent control board1 x EM30-24 Electro-Mechanical Control Panel1 x ACO 149-ACO1/EDV2 x Helios HQW-200/2 - IP552 x BEAS-control module4 x CPTA-S PIR SENSOR Volt Free Contacts - Surface Mounted5 x MWS 1.5 – Transformer Controller With Motor Protection1 x Systemair Save Connect 2.0 Internet Module3 x Elta ACO Panel 149-ACO18B1 x EC-Vent Room Unit2 x Envirovent G4 Filter - SL-G4/F71 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection3 x EC6H - Reversible Group Fan Electronic Controller2 x Single phase speed controller by auto-transformer - RMB 3.5 Amp5 x WS - Reversing Switch from Helios Fans1 x EM30-24 Control Panel Commissioning Service1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6303 x Transformer 5 Speed Controller - ATC1-12TK2 x TG-K3/NTC10-01 - Duct temperature sensor1 x Helios HQW-630/4 - IP552 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5004 x Helios HQW-200/4 - IP552 x Vent Axia T-Series Controller1 x Easy-fix termination kit - High Rise Ventilator - EFT1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)5 x Transformer (silent) speed controller - RE 3.0 Amp3 x Airvent ceiling fan controller2 x Electronic extractor fan speed controller - FSC 1.52 x Multiflow SMB550/4-1AC4 x Commercial Single or 3 phase Fan Reversing Switch - RS12 x Transformer (silent) speed controller - RE 1.5 Amp1 x Transformer Speed Control - RTRE- 12.0Amp1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT2 x Elta Variable Speed Drive IP66 - 0.75KW2 x Quietflow SQS400-1ECL - Centrifugal Box Fan1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp3 x SG-200 Fan Guard for the HQW 2002 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x CBS-60 Outlet Flange for CSB/CBT-601 x DDMP 12-12 3F 1810W M6A4 DG02 x Speed Controller - REB52 x Remote Timer Control - 13511 x MTP 10, 10K, Speed control1 x KMBI 225 Connector rectangular/circular to install on the discharge of CMT3 x Vent Axia Silent 100T (TIMER)1 x DEF-140T Inlet Guard for the CBT-100N1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3552 x TG-R room temperature sensor1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)2 x MV-B Dual Switch for use with Helios HQW plate fans,1 x REE-1 Electronic Speed Controller1 x Elta Variable Speed Drive IP66 - 2.2KW2 x RDH FLEX-SQUARE - ADH/RDH 04501 x TUNE-R-200-3-M1 - Control Damper1 x CBM 9-9 550w 4P VR (Open Motor)1 x KKS 100 silencer-section - For use with the MUB 100 size Fans.
Reviews
Soler & Palau TCBB/4-450/H - IP65
Soler & Palau TCBB/4-450/H - IP65
£ 505.88

Delivered super promptly yesterday, next day. Only just fitt...