Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x Circular Ceiling Diffuser - TST 2001 x Curved Blade Grille 600x600 (2way blow)1 x Round ceiling diffuser 200mm2 x Push Timer Switch - ZA41 x Time Delay Unit - DT20B1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Multi Input Run On Timer - 0 - 20min - CFCU3 x Vent Axia ACM 125 T (Timer Model) inline mixed flow duct fan1 x Balance S Diffuser - NO RING - 100mm2 x Remote Timer Control - 13511 x Elta 3 Amp Electronic single phase speed controller with TK1 x EM30-24 Electro-Mechanical Control Panel3 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans1 x Helios ZNE Electronic Fan Overrun Timer1 x 7 Day Programmable TIMECLOCK2 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)2 x BEAS-control module2 x Elta 6 Amp Electronic single phase speed controller with TK1 x ACO8AC/EC AutoChangeover panel1 x Circular Ceiling Diffuser - TST 1251 x JSR 200 Painted RAL50181 x Circular Ceiling Diffuser - TST 1602 x Systemair Save Connect 2.0 Internet Module1 x Round ceiling diffuser 350mm2 x Vent Axia ACM 125 inline mixed flow duct fan1 x CONTROL ECOWATT - Basic2 x TG-K3/NTC10-01 - Duct temperature sensor1 x EC-Vent control board3 x Transformer (silent) speed controller - RE 3.0 Amp1 x Airvent ceiling fan controller1 x ACO 149-ACO1/EDV2 x Transformer 5 Speed Controller - ATC1-12TK2 x Vent Axia ACM 100 inline mixed flow duct fan2 x Transformer speed controller - ATC1 - 1.5 Amps2 x Isolator Switch - ISOSW2 x Single phase speed controller by auto-transformer - RMB 1.5 Amp2 x TG-R room temperature sensor1 x Transformer 5 Speed Controller - ATC1-4TK2 x Vent Axia ACM 200 inline mixed flow duct fan2 x MWS 1.5 – Transformer Controller With Motor Protection1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x EM30-24 Control Panel Commissioning Service1 x Speed Controller - REB1-N1 x MTP 10, 10K, Speed control2 x Helios HQW-315/4 - IP551 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Transformer 5 Speed Controller - ATC1-2TK1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x DEF-140T Inlet Guard for the CBT-100N1 x TG-K Duct temperature sensor2 x PIR Sensor - PIR21 x Vent Axia Silent 100T (TIMER)1 x MTS10- extractor fan 3 step switch1 x Transformer Speed Control - RTRE- 1.5Amp1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Helios HQW-200/4 - IP551 x Multiflow SMB550/4-1AC
Reviews
EM 250-E2M 01- Etamaster-250
EM 250-E2M 01- Etamaster-250
£ 128.80

Really well made but comes with no speed controler? ?and can...