• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x Transformer (silent) speed controller - RE 1.5 Amp1 x Electronic extractor fan speed controller - FSC 1.51 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6303 x TG-K3/NTC10-01 - Duct temperature sensor1 x Helios HQW-630/4 - IP551 x Helios HQW-200/4 - IP551 x Transformer (silent) speed controller - RE 3.0 Amp1 x Remote Timer Control - 13511 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x Commercial Single or 3 phase Fan Reversing Switch - RS12 x Airvent ceiling fan controller1 x Helios HQW-315/4 - IP552 x TG-R room temperature sensor1 x Speed Controller - REB52 x Speed Controller - REB1-N2 x Transformer Speed Control - RTRE- 1.5Amp1 x CBS-60 Outlet Flange for CSB/CBT-602 x EBM-Papst D4E225-BC01-17 Double inlet1 x MEV Spider Wireless boost Switch - MEV-SWH-W1 x Elta Wall Cowl SWC56/631 x Vent Axia ACM 200 inline mixed flow duct fan1 x Elta 6 Amp Electronic single phase speed controller.1 x Bathroom Fan -Envirovent- Silent 100 T (Timer Model)1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Transformer (silent) speed controller - RE 5.0 Amp1 x REE-2 Electronic Speed Controller2 x MTP 10, 10K, Speed control2 x Elta Variable Speed Drive IP66 - 0.75KW1 x Multiflow SMB550/4-1AC1 x MTS10- extractor fan 3 step switch1 x Single phase speed controller by auto-transformer - RMB 10.0 Amp1 x Speed Controller - REB101 x Transformer Speed Control - RTRE- 7.0Amp1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt CVR1 x Speed Controller - REB82 x DDMP 12-12 3F 1810W M6A4 DG01 x Elta Wall Cowl SWC35/401 x SG-200 Fan Guard for the HQW 2001 x RDS 11 Helios Transformer Controller With Motor Protection1 x ACO8AC/EC AutoChangeover panel1 x Three Phase 3 step - 10amp Transformer controller for use with the HV Wall Mounted fans.1 x EBM-Papst D3G133-BF05-14 Double inlet1 x GRA-100 External Grill by S&P1 x Elta 10 Amp Electronic single phase speed controller.1 x FRQ5-10A Inverter Speed controller1 x Compact SCD450/4-1AC1 x QPTW 250C Acoustic Twin Fan with Controller1 x Elta Wall Cowl SWC45/502 x REB-CVF 0-10v Controller1 x CBP-18/18-RC Belt Driven Centrifugal Fans1 x Elta Variable Speed Drive IP66 - 2.2KW1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x Elta Louvre Shutter - 400mm1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Helios TSW 1.5 Amp Transformer speed controller
Reviews
Duct Mounted Inline Filter - EU4
Duct Mounted Inline Filter - EU4