• Model:N73-31867

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

£ 2,897.00 (excl. VAT)

£ 3,476.40 (inc. VAT)

Rosenberg DKHM 315-2SB.090.6FAIE-VU67

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

PDF Files


Datasheet

1 x UB47- Universal Insulated Terminal1 x DPD 12PM Delivery Surcharge1 x Same Day Shipping Surcharge - City Sprint1 x Northern Ireland Pallet Surcharge1 x DPD 10:30AM Delivery Surcharge1 x D2E-146-AP47-751 x Remote controller FLEX - for VEKO INT1 x Helios TSW 7.5 Amp Transformer speed controller1 x HCFC 1.7 - Reversible Speed Controller for HCF sweep fans2 x Single phase speed controller by auto-transformer - RMB 3.5 Amp1 x Transformer (silent) speed controller - RE 3.0 Amp2 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x Speed Controller - REB1-N1 x QPTW 250C Acoustic Twin Fan with Controller1 x Economy Airvent 150mm Fan With Pullcord & Shutters1 x Economy Airvent 100mm Fan with Timer1 x DV-ROF-V-225 Roof mounted unit1 x RUCK MTP 20, 10K, Speed control1 x Universal Pipe Fixing Clip1 x Manrose Window Extractor - WF150AP1 x DV-ROF-V-315 Roof mounted unit1 x 18M - 80mm PVC flexible ducting1 x Manrose T12 STANDARD Transformer- T12S1 x Manrose 150mm - XF150BHP1 x Economy Airvent 150mm Fan1 x SDD-U Anti Vibration Pads1 x Vent Axia W300310 Controller Electronic 1.5A1 x HXP450/6-1 - 6 Pole - Single Phase1 x HIMF - Mixed Flow Fan 100mm Inline Fan1 x Pallet Delivery Surcharge1 x HPA Heavy Duty Flexible Ducting - HPA300-FD51 x AL 450 EC 03 AXIALINE - High Performance Long Cased Axial Fan1 x CAB-150 ECOWATT Energy Efficient Acoustic Box Fan1 x Vent Axia ACM 150 T (Timer Model) inline mixed flow duct fan1 x Speed controller with Reverse - REB-1R2 x S&P MULTI-REG EC FAN CONTROLLER / INTERFACE1 x Transformer 5 Speed Controller - ATC1-4TK1 x Helios TSW 3 Amp Transformer speed controller1 x RDS 11 Helios Transformer Controller With Motor Protection2 x Vent Axia ACM 100 inline mixed flow duct fan1 x Vent Axia ACM 200 inline mixed flow duct fan1 x DEF-140T Inlet Guard for the CBT-100N1 x Vent Axia ACM 125 inline mixed flow duct fan1 x Single phase speed controller by auto-transformer - RMB 1.5 Amp1 x EFSC-3N- Single Phase Speed Control1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x Remote Timer Control - 13511 x TTC-2000 Three phase electric heater controller1 x ACO8AC/EC AutoChangeover panel1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x Elta ACO Panel 149-ACO14E1 x EC-Vent control board1 x Airvent ceiling fan controller1 x CONTROL ECOWATT - Basic1 x Transformer (silent) speed controller - RE 1.5 Amp1 x TG-K3/NTC10-01 - Duct temperature sensor1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x ACO 149-ACO1/EDV1 x CBS-60 Outlet Flange for CSB/CBT-601 x EM30-24 Electro-Mechanical Control Panel1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x CBM 9-9 550w 4P VR (Open Motor)1 x Transformer Speed Control - RTRE- 1.5Amp1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x KMBI 180 Connector rectangular/circular to install on the discharge of CMT1 x MTS10- extractor fan 3 step switch1 x Systemair Save Connect 2.0 Internet Module1 x Commercial Single or 3 phase Fan Reversing Switch - RS11 x Elta ACO Panel 149-ACO18B1 x Speed Controller - REB11 x REE-2 Electronic Speed Controller1 x MTP 10, 10K, Speed control1 x EM30-24 Control Panel Commissioning Service1 x Elta Variable Speed Drive IP66 - 0.75KW1 x MEV Spider Wireless boost Switch - MEV-SWH-W1 x PIR Sensor - PIR21 x Rectangular Airbrick Adaptor1 x TD Mixvent 800/200 EEXEIIT3
Reviews
Soler & Palau TCBB/4-450/H - IP65
Soler & Palau TCBB/4-450/H - IP65
£ 505.88

Delivered super promptly yesterday, next day. Only just fitt...