• Model:DKHM355-2B.100.6HF

Rosenberg DKHM 355-2 B.100.6HF - N73-35805

£ 1,154.00 (excl. VAT)

£ 1,384.80 (inc. VAT)


Rosenberg DKHM 355-2 B.100.6HF - N73-35805

Rosenberg AC-Radial fans in combination with a voltage-controllable external-rotor motor form a very compact, efficient and optimized fan unit. They impress with low installation depth and a simple installation. Fast start-up is ensured because of well-integrated components.

Applications:
Air Handling Units / Roof Fans / Duct Fans

Motors:
The voltage controllable AC-motors are characterized by a compact, robust design and a good controlling behaviour. They are designed by standard with protection class IP44, thermal class F and ignition protection Ex eb or Ex ec.

Motor Protection:
The winding of the motors feature integrated triple Positive Temperature Coefficient (PTC) thermistor temperature sensors according to DIN 44082, which will have to be connected to a PTC thermistor tripping unit with protective mark Ex II (2)G as a motor protection. This specific thermal motor protection is capable of precisely identifying any abnormal operating condition and external influence and will then disconnect the motor from the mains via a contactor in any conceivable malfunction case. It is permissible to install commercially available motor circuit breakers only as additional safety devices, since they are not able to ensure complete motor protection under all conceivable operating conditions (e.g. operation with reduced-voltage). Electrical connection:
The fans are supplied as standard with a connection cable approx. 0.8 m long. Wiring diagrams are glued to the cable outlet side of the fan housing. An Ex connection box is available as an accessory.

Air volume control: Explosion proof external rotor motors.
The design of the motors allows for a stable modulation of the motor speed via a voltage reduction. Only transformer type open-/closed-loop control units may be used for this purpose. For correct assignment refer to the list of accessories. The permissible voltage modulation range of between 25 and 100 % of the nominal voltage meets the typical requirements of systems with a variable air flow. If the system is operated in the reduced-voltage range, the operating current may exceed the nominal current. The percentage current increase in comparison to the nominal current is listed under technical data as Delta I. Open-/closed-loop control units must be designed to handle the maximum operating current. Ex external rotor motors with type of protection „eb“ or „ec“ are not allowed to be used with frequency converters.

1 x Duct Termination with Mesh - 450mm1 x SPI-150 C Iris damper1 x Singleflow SSDL315-1EC1 x Northern Ireland Pallet Surcharge1 x Duct Tape - High Temperature Resistance 350˚C - DTape3501 x Elta SLC500-1EC -IE5 Motor- IP551 x *VORT HRW 30 MONO Evo - Single Room Heat Recovery Unit,1 x Raptor SDA400/4-1AC1 x Eco-Loft Positive Input Ventilation System - PIV Loft Mounted -EVL-HW1 x Ducting 90 Degree Bend - 800mm1 x Rosenberg E46-35003 Type: AKBD 350-4 B51 x Ducting 90 Degree Bend - 400mm1 x JETLINE-160 - In Line Centrifugal Duct Fan1 x Impeller Side Guard - 500mm1 x HRT/4-500/25-BPN C1 x 150mm - 100mm Stainless Steel Ducting Reducer1 x Acoustic MiniBox Fan - MINI-BOX 1501 x DEXA HR 150 Plus - Single Room MVHR1 x Heat Resistant In-line Axial Fan - VOK 135/120 H1 x Helios SB-160-EC SilentBox Acoustic Inline Fan1 x Elta Variable Speed Drive IP66 - 2.2KW1 x FU 22 25 Frequency Inverter1 x FU 075 52 Frequency Inverter (IP20)1 x Transformer 5 Speed Controller - ATC1-4TK1 x FRQ5-4A V2 Inverter Speed Controller1 x FRQ-10A V2 Inverter Speed controller1 x FU 15 40 Frequency Inverter1 x Helios TSD 3.0 Transformer Speed Control (400v)1 x Elta Variable Speed Drive IP66 - 7.5KW1 x ATEX rated 3-phase Speed Control - R-DK4 KT (EX)1 x Elta 10 Amp Electronic single phase speed controller.1 x Elta Variable Speed Drive IP66 - 2.2KW (1ph to 3ph)1 x FRQ5-10A Inverter Speed controller1 x FU 15 16 Frequency Inverter1 x Elta Variable Speed Drive IP66 - 5.5KW1 x Elta Variable Speed Drive IP66 - 1.5KW1 x Frequency converter RUCK - FU 075 201 x Elta Variable Speed Drive IP66 - 4.0KW1 x Frequency converter FU 075 14 - IP661 x Elta Variable Speed Drive IP66 - 0.75KW1 x Helios - FIUK-11KW 24.0A - FREQUENCY INVERTER1 x FU 075 04 Frequency Inverter (IP20)1 x Frequency converter RUCK - FU 075 211 x FU 22 04 Frequency Inverter1 x ELTA - Single Phase Transformer 2amps1 x Electronic extractor fan speed controller - FSC 1.51 x Elta 3 Amp Electronic single phase speed controller with TK1 x 5-Speed Controller for use with Elta SAX Classic Fans1 x Elta 2 Amp Electronic single phase speed controller.1 x EC6H - Reversible Group Fan Electronic Controller1 x ELTA - Single Phase Transformer 12amps1 x Airvent ceiling fan controller1 x Elta 3 Amp Electronic single phase speed controller.1 x Elta 6 Amp Electronic single phase speed controller with TK1 x ELTA - Single Phase Transformer 16amps1 x EFSC-3N- Single Phase Speed Control1 x Elta 6 Amp Electronic single phase speed controller.1 x EFSC-6N- Single Phase Speed Control1 x COM-31 x ELTA - Single Phase Transformer 4amps1 x ELTA - Single Phase Transformer 10amps1 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x Helios ZNE Electronic Fan Overrun Timer1 x Push Timer Switch - ZA41 x Time Delay Unit - DT20B1 x Multi Input Run On Timer - 0 - 20min - CFCU1 x 7 Day Programmable TIMECLOCK1 x TTC-2000 Three phase electric heater controller1 x ACOAS/ AC/EC Auto Changeover 8Amp1 x ACO8AC/EC AutoChangeover panel1 x Elta ACO Panel 149-ACO14E1 x CONTROL ECOWATT - Basic1 x EC-Vent control board1 x ACO 149-ACO1/EDV1 x EM30-24 Electro-Mechanical Control Panel1 x Elta ACO Panel 149-ACO18B1 x U-EK plastic housing IP65 - for use with the U-EK230E Motor Protection1 x FAST-TRACK RANGE 75mm - Click Ring (1 bag of 10)1 x Systemair Save Connect 2.0 Internet Module1 x EC-Vent Room Unit1 x EM30-24 Control Panel Commissioning Service1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 5001 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 6301 x Easy-fix termination kit - High Rise Ventilator - EFT1 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 3551 x Elta Wall Cowl SWC56/631 x GRA-100 External Grill by S&P1 x Speed Controller - REB81 x Elta Louvre Shutter - 400mm1 x Elta Wall Cowl SWC35/401 x 204x60mm Insulated Rectangular Vertical 45° Bend1 x Elta Wall Cowl SWC45/501 x Elta Wall Cowl SWC25/311 x S & P Aluminium Axial Fan Louvre Shutter - PER-CR- 7101 x Egg Crate Grille with G2 Dust panel filter 1 inch- 300x3001 x Jet Cowl - 315mm1 x Egg Crate Grille with Dust panel filter 1 inch- 595x5951 x Single Deflection Grille 400mm with OBD damper1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR1 x Non Vision 150mm x 150mm (Air Transfer) Grille - With Flange - MILL FINISH1 x Binks Bullows - Spray Booth Filter1 x Mini Diffuser - 100mm1 x Egg Crate Grille with Dust panel filter 1 inch- 300x3001 x MV-Silent 250 Bathroom Extractor Fan Kit - Standard - No Timer1 x D2E-146-AP47-75
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 58.40

I have a loft mount extractor fan which was very noisy. I ...