• Model:2173

SAVE VTC 700 R Heat Recovery Unit

£ 3,149.00 (excl. VAT)

£ 3,778.80 (inc. VAT)

The SAVE VTC 700 is designed for installation on floor, in laundry room, storeroom.

The unit is double skinned, fully insulated and with complete control functions, high efficiency counterflow heat exchanger and filters. Energy efficient fans with EC motors will reduce energy consumption for transportation of ventilation air by apx. 50 % compared to traditional AC motors. Modern technology gives low SFP factor (Specific Fan Power).

The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling).

Airflow and supply air temperature can be set from one or more CD control panels. Symbol and text in the display will indicate chosen settings; re-heater operating, summer operation and need for filter change. Commissioning of airflow on supply and extract, on each step, is set from the control panel. Timer-function for automatic change between day and night operation (installations in commercial buildings) is integrated. Alarm signal will indicate possible malfunctions.

The CD panel also has a user level for authorized installers and service personnel. The CD panel is connected to the unit by means of cable with quick connectors (modular plugs), alternatively via 4-pole terminal block.

The unit is equipped with outputs to control an external hot water battery and inputs prepared for demand controlled ventilation from external sen-sors, e.g. CO2, presence or humidity sensor (potential free contact). Unit is delivered with a built-in moisture sensor that not only provides you demand controlled ventilation as standard but also is used for detecting and control defrosting in colder climate.

The unit has an automatic defrost function with the built in moisture sensor that can be chosen in 3 different modes depending on the indoor environment as well as the outdoor conditions. Without preheater in tight houses / passive houses where unbalanced airflow is not allowed the unit works down to -5°C. Without preheater when unbalance is allowed the unit works down to -15°C. Below -15°C a preheater is needed.

The VTC 700 can be supplemented with a re-heater battery  G4 filters are delivered as standard. F7 and M5 are availabe as accessories.
1 x Remote Timer Control - 13511 x Run On Timer - 5s - 4hrs - RT5A1 x AKOR Spare Filter1 x 7 Day Programmable TIMECLOCK1 x KABT High Temp Acoustic Kitchen Fan & Inverter Kit - KABT/4-6000/450 ND - Pack 31 x CCZ-404-T (three Phase)1 x Helios ZNE Electronic Fan Overrun Timer1 x AL 400 D2 01 AXIALINE - High Performance Long Cased Axial Fan1 x HRFD 400/4/2 Cased Axial Fan 400mm - 3 Phase1 x Raptor SDA400/4-1AC1 x Etaline 280mm1 x Etaline 250mm1 x FU 15 40 Frequency Inverter1 x Acopel F400-200/1601 x SAVE VTC 200 L High efficiency Heat Recovery Unit1 x FRQ5-10A Inverter Speed controller1 x Acopel F400-400/1601 x SAVE VTC 700 L Heat Recovery Unit1 x Elta SCP315-1EC - IP551 x HIMF - Mixed Flow Fan 125mm Inline Fan1 x Insulated extract Plenum 6+11 x Jetflow-HIT Metal inline - 150mm1 x HCFB/4-315mm (B-FLOW Supply Air) plastic impeller plate fan1 x Etaline 400mm D2-01 3-phase1 x Acopel F400-250/1601 x SAVE VTC 200 R High efficiency Heat Recovery Unit1 x EBM-papst Motorised Impeller - A6D800-AD01-011 x Elta SPA710/4/6-3AC - IP541 x Flanged Spigot - 630mm1 x Soler & Palau - Contra Rotating TCBTx2-500 - IP651 x Metal Inline Fan - VENT-400K - T (3 Phase)1 x Acoustic Box Fans (Inline) - CAB-1501 x Elta Turboflow-TF - 500mm(A) - Three phase1 x Elta SLC500/4A-1AC - IP551 x Systemair AW Sileo 710-DS1 x Spare filter Set for Energi Sava 300 & 400 HR unit1 x Helios VARW 225/4 High Pressure Duct Fan1 x CRBB-2-220-063M1 x Acopel F400-900/1801 x Soler & Palau HXM-350mm1 x HRT/6-710/30-BQ E21 x Quietflow SQS150-1ECL - Centrifugal Box Fan1 x Soler & Palau - HCBT/2-315/H - IP65