• Model:SAVE-VTR150S

SAVE VTR 150/K Heat Recovery & Cooker Hood (Stainless Steel)

£ 2,925.54 (excl. VAT)

£ 3,510.65 (inc. VAT)

• High efficiency rotary heat exchanger with EC- variable speed rotor motor
• Energy efficient RadiCal-fans, with EC-technology enables very low SFP and low sound
• Moisture transfer function to minimize condensation to supply air in wintertime is available
• Demand control regulation as standard by the built-in humidity sensor in extract air
• SAVECair control with a capacitive color touch screen for easy use and commissioning
• Connection box outside of unit for easy installation
• Modbus communication via RS-485 as standard
• Internet communication over the Systemair cloud (IAM) is available as accessory

SAVE VTR 150/K is adapted for ventilation of smaller houses and apartments with an area of 100 m². Left and right handed models are available.

SAVE VTR 150/K has an integrated cooker hood and should be placed above the hob. The unit with modern design suits different kitchen environments. The integrated cooker hood has push buttons for the damper, forcing and lighting. The damper is opened during food preparation by pushing the button once. Pushing it second time will force the ventilation and a third time will close the ventilation damper in the cooker hood and the unit will go back to normal operation.The extract air from the cooker hood is being by-passed, so the heat exchanger is not being exposed to extract air from the kitchen.

SAVE VTR 150/K SS is a unit with stainless steel double skinned panels and comes with complete control functions. The unit is equipped with a high efficiency variable speed rotating heat exchanger and a moisture transfer function that regulates the rotation speed of the rotor due temperature and moisture transfer back to supply air. Energy efficient fans with EC motors as well as low pressure filters reduces the energy consumptions and gives low SFP factor (Specific Fan Power) and low sound. The built in humidity sensor in extract air can be used for demand control.

All settings and features are available from the SAVECair control panel that connects to the top of the unit via the connection board and can be positioned on the wall or on the unit. The panel is a color touch screen with a user friendly interface. The option for connecting one or more external control panels is available. Also control panel has separate user level for authorized installers and service personnel.

The homepage of the control panel shows information such as airflow, temperature, air quality and active functions. You can select between MANUAL and AUTO mode or choose preferred settings from the pre-configured user modes.

SAVECair AUTO mode has many functions available that regulate the airflow according to CO2, presence, humidity, schedule etc. The demand function control gives effective and economical operation to ensure best indoor air quality. Alarm symbols will indicate possible malfunctions and issues direct alerts if anything needs to be rectified.

The unit comes with built-in electric reheater.

The unit is provided with a connection board that has prewired inputs and outputs for easy installation and setup of external sensors as well as for external heaters / coolers.
The unit is delivered with low pressure panel filters:
Supply air filter M5
Extract air filter M5
Low pressure panel filter F7 is available as an accessory for supply air filtering.

Note: No continuous ventilation through the cooker hood.

Download datasheet HERE.

Available Options

1 x Acoustic Box Fans (Inline) - CAB-2001 x RDS 7 Helios Transformer Controller With Motor Protection1 x CBMT/Q 250-54 1 HEATER KIT1 x SAVE VTC 200 L High efficiency Heat Recovery Unit1 x SAVE VSR 300 heat recovery unit1 x Kitchen Grease Filter - Mesh Type Non standard 275mm x 180mm x 22mm1 x Duct Suspension Rings - 355mm1 x 125mm - 150mm Round Reducer1 x Ducting 90 Degree Bend - 150mm1 x TechSeal 100FR Duct Sealant Cartridge - 100FRS1 x CADB/T-HE PRO-REG Series1 x Spiral Ducting 3 Meters - 450mm1 x Spiral Ducting 3 Meters - 180mm1 x HR-500 DP Heat Exchange Unit1 x Filter Box With F7 Grade Bag Filter - 150mm1 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 630mm1 x Kitchen Grille with Grease Filter - 300x300 - NO GRILLE BOX1 x Elta SCP500/4-3AC - IP551 x AKOR Spare Filter1 x Female Ducting Connector - 150mm1 x Ducting 45 Degree Bend - 150mm1 x AKOR T3/7 Spare Motor1 x *VORT HRW 40 MONO Evo HCS WIFI - Single Room Heat Recovery Unit,1 x GENIOX 11 Internal Mounted Unit1 x MTP 10, 10K, Speed control1 x REB Ecowatt Speed Control - REB-ECO1 x Spiral Ducting 3 Meters - 900mm1 x Soler & Palau - HXBR/4-355/H - IP541 x Jetflow-HIT Metal inline - 150mm1 x Spare filter Set for Energi Sava 300 & 400 HR unit1 x Spiral Ducting 3 Meters - 710mm1 x Villiavent VSR 300 Spare Motor1 x M5/G4 filter kit for IDEO HR unit1 x Vent Axia INTEGRA PLUS EC1 x Spiral Ducting 1 meter - 710mm1 x Elta Variable Speed Drive IP66 - 0.37KW (1ph to 3ph)1 x SAVE VTC 700 R Heat Recovery Unit1 x Vent Axia ACM 100 T (Timer Model) inline mixed flow duct fan1 x Universal Pipe Fixing Clip1 x AKOR Mounting Plate for GD model(VIM166423)1 x Ancillary Pack for SB-Biflow 400 model1 x Spare filter pack for Energi Sava 210 HR unit
Air Quality Sensor - AQS
Air Quality Sensor - AQS
£ 98.29 now £ 65.00
Reviews
DAOSL Back Draft Damper
DAOSL Back Draft Damper
£ 10.53

Look good, works well, except the shaft of the lanellae cuts...