The Sentinel single in-line duct fans are as supplied from Vent-Axia Ltd. Manufactured from Aluzinc, Sentinel fan units are internally treated with an ‘O’ class rated, BS476 part 6 & 7 acoustic foam which offers the benefits of high sound absorption, good thermal insulation properties, in addition to self extinguishing properties and resistance to ignition.

Weatherproof external units incorporate an additional controller shroud.
The casing includes an inclined inlet and bellmouth entry which directs the incoming air to the impeller with minimal turbulence. The result is better air management through the unit, less noise, higher efficiency and an increased performance.
The housing is designed to be as compact as possible for concealed false ceiling applications and Sentinel casings are specially designed to allow the unit to be mounted via its unique mounting bracket, ensuring a quick and easy solution to installation.

Impellers

All Sentinel units feature a low energy, Class 1, EC/DC external rotor motor and backward curved impeller assembly specifically chosen for performance and non-overloading characteristics. The assembly is dynamically balanced to DIN ISO 1940 Grade 6.3, duct size 500mm rated IP54, all other sizes IP44 according to BS EN 60529. Ball bearings are greased for life. Insulation is Class ‘B’ (from -25°C to +60°C). All models incorporate internal electronic overload protection and soft start function.

Electrical

Every Sentinel unit is fitted with a purpose designed common PCB controller incorporating a 16-character backlit alphanumerical x 2 line display with 4 button membrane keypad for fan status and commissioning set up. The enclosure is fitted with a 4-pole 10A isolator that is suitable for fitting a locking device to prevent accidental operation.

Motors are single phase 230V +/- 10% / 50/60Hz / 1ph (size 100- 400mm) or 400V +/- 10% / 50/60Hz / 3ph (size 500mm), (4 wire systems only).

24V DC power is provided from the controller for powering the matched range of Sentinel switches and sensors.

Performance/Sound

Extensively tested to BS848 parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at reference level of 2 x 10-5 Pa. The inlet/outlet sound power level spectra figures are dB with a reference of 10–12 Watts.
Weatherproof Typical Ordering Designation

Ordering codes are similar to existing units with Suffix…. /WP which denotes Weatherproof.

Example: SENT100S/CP/WP

Accessories

For duct accessories see Ducting and Fitting Section.
1 x CBA-60 Inlet Flange for CBT-602 x DDMP 09-09 3F 2130W M6A4 DG01 x Transformer (silent) speed controller - RE 1.5 Amp1 x Speed Controller - REB51 x CBM 9-9 550w 4P VR (Open Motor)3 x SG-200 Fan Guard for the HQW 2001 x MTS10- extractor fan 3 step switch1 x RDS 11 Helios Transformer Controller With Motor Protection1 x Elta 6 Amp Electronic single phase speed controller.1 x TD Mixvent 800/200 EEXEIIT31 x REB-CVF 0-10v Controller2 x DDMP 09/09 Mounting Flange1 x Speed Controller - REB12 x Helios HQW-250/4 - IP551 x QPTW 250C Acoustic Twin Fan with Controller1 x Multiflow SMB550/4-1AC1 x CBM Low Pressure Centrifugal Fan - CBM 10/10 4 Pole 550watt VR2 x Compact SCD450/4-1AC1 x DDMP 12-12 3F 1810W M6A4 DG03 x CBA-100 Inlet Flange for CBT-1001 x CCpro 40 (1CC9402) Long Casing Extension2 x Vent Axia ACM 200 inline mixed flow duct fan2 x EBM-Papst D4E225-BC01-17 Double inlet2 x RDH FLEX-SQUARE - ADH/RDH 04502 x RD35S-4DW.6W.3L - 122297 (Three Phase)1 x Silent 100 Window Kit - windowS1 x Elta Variable Speed Drive IP66 - 7.5KW2 x Comefri - TLZ 560 R - High Performance Scroll Fan2 x Comefri - TLZ 225 R - High Performance Scroll Fan1 x Comefri - TLZ 450 R - High Performance Scroll Fan1 x Elta - Room Sensor - Temp/Humid/C022 x ADH E0-450 Flange - 0450 ADHE/RDHE1 x CBT-130N Centrifugal ATEX II 2G Exd IIB T41 x ELTA - Single Phase Transformer 2amps2 x CBT-130N Centrifugal ATEX II 3D ExtD 125*C1 x VEKA INT 2000/15.0-L1 EKO1 x CBT-100N Centrifugal ATEX II 2G Exe II T31 x CMT-2 120/50 - 0,09Kw - LG270 Single inlet centrifugal fan direct driven1 x Transformer Speed Control - RTRE- 5.0Amp1 x DDMP 07/07 Mounting Flange1 x Nicotra RDH G2E7-04501 x DDMP 12-12 1F 1800W M6A4 DA81 x Flanged Damper 019-0560-STD1 x DDMP 10-08 FLANGE1 x CBA-130 Inlet Flange for CBT-1301 x EC Trickle and boost module - IP561 x CBM Low Pressure Centrifugal Fan - CBM 9/7 4 Pole 373watt CVR1 x Duct Termination with Mesh - 710mm1 x DDMP 09/07 Mounting Flange1 x ELTA - Three Phase Transformer 3amps1 x Elta Standard Ambient Flexible Connector - 800mm1 x Electronic extractor fan speed controller - FSC 1.51 x Round ceiling diffuser 250mm1 x RUCK MTP 20, 10K, Speed control1 x ADH E0-250 Flange - 0250 ADHE/RDHE1 x ERR 20/1 Centrifugal inline fan1 x Potentiometer EGH 01 - for DDMP Fans1 x Transformer Speed Control - RTRE- 7.0Amp1 x Transformer 5 Speed Controller - ATC1-12TK1 x Vent Axia ACM 150 inline mixed flow duct fan1 x Vent Axia ACM 100 inline mixed flow duct fan1 x Envirovent Silent MV160/100T Mixvent - Timer Model - 100mm - (5 year warranty)1 x Vent Axia T-Series Controller1 x Two Speed Switch - REGUL-21 x Vent Axia Silent 100T (TIMER)1 x Clearflow CF Roof Mounted Vertical Discharge Centrifugal Fan - CF400/4-1AC - Single Phase1 x Multi Input Run On Timer - 0 - 20min - CFCU