• Model:CC-SHT(5.5kw

CC-SHT 1004 (5.5kw)

£ 2,118.90 (excl. VAT)

£ 2,542.68 (inc. VAT)

High efficiency duct axial fans designed for high temperature smoke extraction.
CC SHT fans are specifically dimensioned in a standard range suitable for the performance ratings which are normally requested by the building ventilation fire smoke exhaust rules.
The series is suitable for running at the temperature of +60°C and is CE certified F300, F400
(except 2 poles versions, certifi ed F300/120)
according to EN 12101-3 and guaranteed to operate at 300°C for 2 hours by the independent notified body Applus.
CONSTRUCTION
• Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EURO-VENT standard. Protected against atmospheric agents by epoxy paint.
• High efficiency axial impeller in die-cast aluminium with aerofoil profile blades, totally made. Balanced according ISO 1940. Variable pitch angle in still position.
• Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motor.
• Asynchronous three-phase motors according to international standards IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F or H, F200, F300 or F400 certified according to the European Directive EN 12101-3.
Horizontal axis as standard (other orientations on request).
ACCESSORIES
• Extension with inspection door (CCpro)
• Inlet cone (CCbo)
• High tempeeration fl exible joint (CCga-HT)
• Flat protection grid (CCr)
• Support feet (CCst)
• Counter-fl ange (CCf)
• Counter-fl ange with collar (CCfc)
• Cylindrical silencers (CCsa/CCsb)
• Roof terminal (Kit TAV-HT)
• Anti-vibration mounts
UPON REQUEST
• External terminal box for high temperature, assembled
1 x Elta SLC900/8-3AC1 x Flanged Spigot - 150mm1 x Elta SLC900/4A-3AC - IP551 x 220x90mm Mounting Clip (Individual)1 x HV Wall Mounted Belt Drive Fan 1000mm 400V / 50Hz 0.75kW - Three Phase1 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 400mm1 x Belt Drive Cased Axial Fan - 630mm - L version1 x ACO3/BD Changover Panel (Three Phase)1 x Helios TSW 1.5 Amp Transformer speed controller1 x Ducting 90 Degree Bend - 315mm1 x Helios GigaBox 400mm GBD 400/4/4 T120 centrifugal1 x Belt Drive Cased Axial Fan - 500mm - L version1 x Belt Drive Cased Axial Fan - 450mm - H version1 x Biflow SB250-CON4-3 - High Temperature Bifurcated Fan1 x Belt Drive Cased Axial Fan - 560mm - H version1 x CTHT Kitchen/High Temp Roof Fan- 400mm1 x AW Sileo EC Plate Axial Fan - Three Phase - 1000mm1 x AXC 315-6/11-2(B)-PV 300*C - Smoke Extract Fan1 x ILHT/4-400 CC - High Temp Kitchen Duct Fan1 x CC-SHT 1004 (5.5kw)2 x Belt Drive Cased Axial Fan - 800mm - L version1 x Soler & Palau - HCBT/4-1000/L - IP551 x Helios GigaBox 355mm GBW 355/4 T120 centrifugal1 x Smoke Extract Axial Fan Series AXC 1000 (B)1 x KBR 315D2 IE2 Thermo fan1 x HCFT/6-1000-HX plastic impeller plate fan1 x Belt Drive Cased Axial Fan - 450mm - L version1 x FSAF630B2DA Silencer1 x Soler & Palau - HCBT/6-1000/H - IP551 x Female Ducting Connector - 630mm1 x Belt Drive Cased Axial Fan - 710mm - H version1 x Clearflow CFHT Kitchen/High Temp Roof Fan - CFHT450/4-3AC1 x Belt Drive Cased Axial Fan - 500mm - H version1 x Flexible PVC Ducting - 220x901 x AXC 355-6/19°-2(B)-P (0.75 kW) - Smoke Extract Fan1 x Biflow SB250-CON4-1 - High Temperature Bifurcated Fan1 x CHGT/4-630-6/-3KW- AXIAL FLOW CABINET FANS