• Model:CC-SHT314

CC-SHT 314 (4-pole)

£ 594.29 (excl. VAT)

£ 713.15 (inc. VAT)

High efficiency duct axial fans designed for high temperature smoke extraction.
This is 4 pole version rated at F300/120.(300 Degrees C for 2 hours)
CC SHT fans are specifically dimensioned in a standard range suitable for the performance ratings which are normally requested by the building ventilation fire smoke exhaust rules.
The series is suitable for running at the temperature of +60°C and is CE certified F300, F400
(except 2 poles versions, certified F300/120)
according to EN 12101-3 and guaranteed to operate at 300°C for 2 hours by the independent notified body Applus.
CONSTRUCTION
• Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EURO-VENT standard. Protected against atmospheric agents by epoxy paint.
• High efficiency axial impeller in die-cast aluminium with aerofoil profile blades, totally made. Balanced according ISO 1940. Variable pitch angle in still position.
• Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motor.
• Asynchronous three-phase motors according to international standards IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F or H, F200, F300 or F400 certified according to the European Directive EN 12101-3.
Horizontal axis as standard (other orientations on request).
ACCESSORIES
• Extension with inspection door (CCpro)
• Inlet cone (CCbo)
• High temperation flexible joint (CCga-HT)
• Flat protection grid (CCr)
• Support feet (CCst)
• Counter-fl ange (CCf)
• Counter-fl ange with collar (CCfc)
• Cylindrical silencers (CCsa/CCsb)
• Roof terminal (Kit TAV-HT)
• Anti-vibration mounts
UPON REQUEST
• External terminal box for high temperature, assembled
PDF Files


Data Sheet

1 x Elta SCP400/4-3AC - IP551 x Eco Hand Drier1 x HD Series Control Damper - 2300mm X 1000mm1 x Soler & Palau - HCBT/4-1000/L - IP551 x Soler & Palau - HCBT/6-1000/H - IP551 x HCFT/6-1000-HX plastic impeller plate fan1 x TUNE-R-200-3-M4 - Control Damper1 x TUNE-R-160-2-M3 - Control Damper1 x TUNE-R-140-3-M4 - Control Damper1 x TUNE-R-250-2-M2 - Control Damper1 x ELTA - Three Phase Transformer 10amps1 x Male Ducting Connector - 400mm1 x Flexible PVC Ducting - 15 Mtr1 x HRT/4-500/35-BPN1 x SPI-200 C Iris damper1 x RSK450 - Back Draught Shutter1 x Jetflow-HIT Metal inline - 315mm1 x OBD 450x450 - for use with 4WAY-5951 x Hydor HPA250/2-11 x Ducting T Piece Equal - 560mm1 x KVK Slim 100 - Low profile Semi Acoustic Box Fan1 x Multileaf Volume Control Dampers -600/600 Rectangular Flanged1 x SPI-315 C Iris damper1 x HD-LL Series 600x6001 x SPI-250 C Iris damper1 x SPI-100 C Iris damper1 x Multileaf Volume Control Dampers -500/500 Rectangular Flanged1 x Ducting Reducer Long - 1000mm to 630mm1 x HD Series Control Damper - 2000mm X 1000mm1 x HD Series Control Damper - 3000mm X 1500mm1 x HD Series Control Damper - 1000mm X 1000mm1 x HV Wall Mounted Belt Drive Fan 1000mm 220V to 240V / 50Hz 0.75kW - Single Phase1 x Rosenberg DQ 1000-8 plate axial fan1 x 204x60mm Flat Channel Connector1 x 204x60mm 45 Degree Horizontal Bend1 x TUNE-R-100-3-M4 - Control Damper1 x Insulated extract Plenum 8+11 x TUNE-R-100-2-M1 - Control Damper2 x TUNE-R-250-3-M5 - Control Damper1 x TUNE-R-250-1-M1 - Control Damper1 x TD160 Mixvent - 100mm - TD160-N Standard1 x TUNE-R-100-2-M5 - Control Damper1 x TUNE-R-180-2-M5 - Control Damper1 x SS Series Slimseal 800mmx800mm Damper1 x TUNE-R-200-3-M0 - Control Damper (NO ACTUATOR)1 x Stainless Steel Single Blade Regulating Damper -200mm1 x Ancillary Sealing Band - 200mm1 x TUNE-R-160-2-M1 - Control Damper1 x TUNE-R-200-3-M3 - Control Damper1 x TUNE-R-400-1-M3 - Control Damper2 x TUNE-R-250-3-M1 - Control Damper1 x TUNE-R-560-2-M1 - Control Damper1 x TUNE-R-250-3-M0 - Control Damper (NO ACTUATOR)1 x TUNE-R-160-3-M4 - Control Damper1 x TUNE-R-80-2-M3 - Control Damper1 x TUNE-R-400-3-M0 - Control Damper1 x Flanged Spigot - 400mm