• Model:RTRE-3.0

Transformer Speed Control - RTRE- 3.0Amp

£ 192.14 (excl. VAT)

£ 230.57 (inc. VAT)

Systemair single phase auto transformer rated from 3.0 amps max, c/w thermal cut out connection.

Single phase transformer which controls the fan speed by altering the supply voltage in five fixed steps. An integral motor protection device is included which cuts the supply voltage to the fan if the thermal contact in the fan motor is activated.

The RTRE has input terminals for room thermostat RT, which stops the supply voltage to the fan when the circuit is broken. The transformer has 230V terminals for operating dampers, electric water-heater batteries or other external equipment.

These terminals have no current when the transformer knob is in position 0, or when the TK or RT input is open. The indicator lamp on the front shows when the transformer is in operation. The fuse may be reset from outside.

• Supply voltage: 230V 50/60Hz.
• Self-extinguishing thermoplastic casing.

Commercial Thermostat, try the TH-16

For the non thermal cut-out version, try the RE
PDF Files


RTRE - 3.0 Amp Specification Sheet

1 x Elta Variable Speed Drive IP66 - 2.2KW1 x CHVB/4-3000/315 0,27KW 230V50 VE1 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 630mm1 x CMT-2 280-115 3KW - Single inlet centrifugal fan direct driven1 x Bifurcated Fan - TET 6/6001 x Impeller Side Guard - 400mm1 x Spiral Ducting 1 meter - 450mm1 x Elta SCP350/4-1AC - IP551 x Elta SPA400/4-1AC - IP541 x Vent Axia SABRE Plate Mounted Sickle Fans - VSP400141 x Elta 3 Amp Electronic single phase speed controller with TK1 x Elta Cased Axial Flange - 400mm1 x CMT-2 120/50 - 0,09Kw - LG270 Single inlet centrifugal fan direct driven1 x AXCBF 315-7/30-2 (0.75 kW) - Bifurcated Axial Fan1 x CMT-2 250-100 3KW - LG0 Single inlet centrifugal fan direct driven1 x CBP-DC 15/151 x CBT-80N Centrifugal1 x CMT-2 250-100 2.2KW - LG270 Single inlet centrifugal fan direct driven1 x AXCBF 400D4-32° (0,55 kW)1 x CBT-125 Centrifugal1 x CMT/4-280-115 2.2KW - Single inlet centrifugal fan direct driven ( LG-90)1 x CBB-60N Centrifugal1 x Chaysol SA 18/8 RTC CW-single inlet centrifugal fan1 x CMT-2 280/115 4KW - Single inlet centrifugal fan direct driven1 x CMT-2 225/090 1.1KW - Single inlet centrifugal fan direct driven1 x CBT-170 Centrifugal1 x Flanged Spigot - 150mm1 x CMRT/2-451 7,51 x CMT/4-315/130-4KW - Single inlet centrifugal fan direct driven1 x CMT-2 200/80 1.1KW - Single inlet centrifugal fan direct driven1 x CBPx2-9/7-D1 x CBP-DC 18/181 x CBT-130N Centrifugal1 x CMRT/2-251 0.37Kw Centrifugal single inlet fan1 x Chaysol SAP 18/8 1.5kW 700r.p.m. CC CW V5-single inlet centrifugal fan1 x Biflow SB (CYL) Bifurcated Cylindrical Axial Flow Fan - 400mm1 x Revolution SLCX ATEX Long Cased Axial Flow Fan SLCX400/4-3 Three Phase1 x CMB-2-140-050 0.25Kw LG O1 x CMT-2 225/090 2.2KW - Single inlet centrifugal fan direct driven1 x CBB-100N Centrifugal1 x CMT-2 160-60 0.37KW - LG270 Single inlet centrifugal fan direct driven1 x AXCBF 315D4-32 Bifurcated Axial Fan1 x CBB-80N Centrifugal
Reviews
Circular Inline Silencers - 0.6M long - SLU-600
Circular Inline Silencers - 0.6M long - SLU-600
£ 50.56

I have a loft mount extractor fan which was very noisy. I ...